Chapter 19, Problem 1RQ
To determine

The recommended repair for a defective relay.

Expert Solution & Answer
Check Mark

Answer to Problem 1RQ

The recommended repair for a defective relay is to replace it.

Explanation of Solution

The relay is a switching device and it works to isolate or change the state of an electric circuit from one state to another state. The classification of the relay is based on its function. The some types of relay are listed below.

  1. Monitoring relay.
  2. Protective relay.
  3. Auxiliary relay.
  4. Regulating relay.
  5. Reclosing relay.

These different types of relays have different application in different types of fields such as motor control, electrical fuel pump, in controlling large power loads and high voltage. The most important advantage of the relay is that it takes a relatively small amount of power to operate the relay coil. It can be also used to control the motors, lamps, or heaters.

The relay is manufactured by the magnetic coil which is considered to be a throw away device. Due to the parts in the relay, it is not available for the rebuilding or repairing it. Therefore, the recommended repair for the defective relay is to replace it.

Conclusion:

The recommended repair for a defective relay is to replace it.

Want to see more full solutions like this?

Subscribe now to access step-by-step solutions to millions of textbook problems written by subject matter experts!
Students have asked these similar questions
This is an old practice exam question.
Steam enters the high-pressure turbine of a steam power plant that operates on the ideal reheat Rankine cycle at 700 psia and 900°F and leaves as saturated vapor. Steam is then reheated to 800°F before it expands to a pressure of 1 psia. Heat is transferred to the steam in the boiler at a rate of 6 × 104 Btu/s. Steam is cooled in the condenser by the cooling water from a nearby river, which enters the condenser at 45°F. Use steam tables.   NOTE: This is a multi-part question. Once an answer is submitted, you will be unable to return to this part.   Determine the pressure at which reheating takes place. Use steam tables. Find: The reheat pressure is  psia. (P4)Find thermal efficiencyFind m dot
Air at T1 = 24°C, p1 = 1 bar, 50% relative humidity enters an insulated chamber operating at steady state with a mass flow rate of 3 kg/min and mixes with a saturated moist air stream entering at T2 = 7°C, p2 = 1 bar. A single mixed stream exits at T3 = 17°C, p3 = 1 bar. Neglect kinetic and potential energy effects Determine mass flow rate of the moist air entering at state 2, in kg/min Determine the relative humidity of the exiting stream. Determine the rate of entropy production, in kJ/min.K
Knowledge Booster
Background pattern image
Mechanical Engineering
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, mechanical-engineering and related others by exploring similar questions and additional content below.
Similar questions
SEE MORE QUESTIONS
Recommended textbooks for you
Text book image
Refrigeration and Air Conditioning Technology (Mi...
Mechanical Engineering
ISBN:9781305578296
Author:John Tomczyk, Eugene Silberstein, Bill Whitman, Bill Johnson
Publisher:Cengage Learning
Text book image
Understanding Motor Controls
Mechanical Engineering
ISBN:9781337798686
Author:Stephen L. Herman
Publisher:Delmar Cengage Learning
Text book image
Welding: Principles and Applications (MindTap Cou...
Mechanical Engineering
ISBN:9781305494695
Author:Larry Jeffus
Publisher:Cengage Learning