The scale of the USGS 7 1/2- minute quadrangle map

Answer to Problem 18.1P
1:24,000
Explanation of Solution
Given Information:
USGS 7 1/2 - minute quadrangle map
USGS map divides the area into quadrangle map shown by area in the terms of latitudes and longitudes within 2 lines. 7.5 minute shows the area bounded by 7.5-degree latitude and 7.5-degree longitude. Scale of 1:24,000 provides enough details through the quadrangle map.
Most of the natural features and geographical information is shown in the scale of 1:24,000 and these maps are generally used by engineers, architects, city planners, etc. Other maps with larger scale are also available such as 1:50,000 and 1:1,00,000 and these maps are preferred for management activities and land use pattern identification.
Want to see more full solutions like this?
Chapter 18 Solutions
ELEMENTARY SURVEYING LL W/MASTERING ENGR
- Solve for reactions and shear and moment diagram (base the answer on the 2nd figure). Hand Calculation 2. Note: Assume bottom left support as roller, bottom right support as pinned 4 kN/m 3 kN/m 8m 4m 2marrow_forwardYour client wants to build a WTP that has a withdraw of 440 MGD. What is the exceedance probability in percentage? Average Monthly Minimum Flow of Record Month (MGD) Jan-73 322 Feb-73 280 Mar-73 335 Apr-73 374 May-73 440 Mar-74 313 Apr-74 375 May-74 560 Jun-74 380 Jul-74 445 Aug-74 323 Sep-74 411 Oct-74 541 Nov-74 510 Jan-75 261 Feb-75 271 May-75 312 Jun-75 314 351 Jul-75 Aug-75 332arrow_forwardIf a second 12.25" pump was added in parallel what would be the NPSHr be while both pumps are running? HEAD (Feet) 250- 200- Pump Series: VSX-VSC 10x12x13-1/2A 1780 RPM 13.5" 60% 70% -75% 80% 83% -85.5%- 150- 12.25" 100- 50 50- 10" 0- 2,000 NPSHr 83%. 80% 300HP- -75% 250HP 200HP 70% 150HP 125HP 100HP NPSHr(ft) 0 4,000 6,000 8,000 Capacity (GPM) 80 90 8arrow_forward
- Solve for reactions and shear and moment diagram (base the answer on the 2nd figure) 1. Note: Assume bottom support as pinned 14 kN/m 16 kN 6m 5m 3m- 6marrow_forwardA plant treats 25 MGD at 5°C and pH=7.0. The plant uses ozone before the filter and free chlorine after the filter. The ozone contactor has a t10 of 3 minutes and a residual concentration of 0.3 mg/L. The free chlorine contact basin is 65 ft by 214 ft by 10 ft and a baffle factor of 0.5 and a residual concentration of 1.4 mg/Larrow_forwardA3-inch diameter water pipe carries a flow rate of 6 gallons per minute. The pipe is 100 feet long and has a gate valve, two 45-degree elbows, and a sudden c factor for the pipe is 0.02 and the minor loss coefficients for the gate valve, elbows, and contraction are 12, 1.5, and 0.5, respectively. Determine the head loss due to friction and minor losses in the pipe, assuming the water temperature is 68°F and the density of water is 62.4 barrow_forward
- Based on ONLY on the diagram below, how much energy is the pump adding to the system. The pressure gauge Reads 60 psi 20 feet 30 feet 5 feet 1 foot 2 feetarrow_forwardA confined aquifer has a differential drawdown (Ah) of 5 feet. The flow rate (Q) is measured to be 10 gpm. Calculate the transmissivity (T) of the aquifer in gpd/ft.arrow_forwardMatch the term from the Clean Water Act with its corresponding definitions National Pollutant Discharge Elimination System (NPDES) Total Maximum Daily Load (TMDL) Best Available Technology (BAT) Point source pollution A The maximum amount of a pollutant that a water body can receive while still meeting water quality standards. B. A permit program that regulates the discharge of pollutants from point sources into the waters of the United States. C. A specific location, such as a pipe or ditch, from which pollutants are discharged into a water body. D. A technology or treatment method that is determined to be the most effective way to control pollutants based on factors such as cost and feasibility.arrow_forward
- Each gate of the lock is 6 m high and is supported by two hinges placed on the top and bottom of the gate. When the gates are closed, they make an angle of 120º. The weight of the lock is 5 m. If the water levels are 4 m and 2 m upstream and downstream, respectively, determine the magnitude of forces on hinges due to the water pressure.arrow_forwardQuestion 5 A submerged sharp crested weir 0.8 m high stands clear across a channel having vertical sides and a width of 3 m. The depth of water in the channel of approach is 1.25 m and 10 m downstream from the weir, the depth of water is 1 m. Determine the discharge over the weir in liters per second. Take Cd as 0.6arrow_forwardQuestion 4 B A rectangular sharp crested weir is to be constructed in a testing station with a small stream in which the discharge varies from 50 liters/s and 1250 liters/s. Find the suitable length of the weir, if the minimum head to be measured is 50 mm and the maximum head on it does not exceed one-third of its length.arrow_forward
- Structural Analysis (10th Edition)Civil EngineeringISBN:9780134610672Author:Russell C. HibbelerPublisher:PEARSONPrinciples of Foundation Engineering (MindTap Cou...Civil EngineeringISBN:9781337705028Author:Braja M. Das, Nagaratnam SivakuganPublisher:Cengage Learning
- Fundamentals of Structural AnalysisCivil EngineeringISBN:9780073398006Author:Kenneth M. Leet Emeritus, Chia-Ming Uang, Joel LanningPublisher:McGraw-Hill EducationTraffic and Highway EngineeringCivil EngineeringISBN:9781305156241Author:Garber, Nicholas J.Publisher:Cengage Learning