EBK ELECTRICAL WIRING RESIDENTIAL
19th Edition
ISBN: 9781337516549
Author: Simmons
Publisher: CENGAGE LEARNING - CONSIGNMENT
expand_more
expand_more
format_list_bulleted
Concept explainers
Question
Chapter 16, Problem 12R
To determine
Explain the term “cover”.
Expert Solution & Answer
Trending nowThis is a popular solution!
Students have asked these similar questions
To testing installation of grounds, the usual procedure is to connect one lead of the megohmmeter to one of the conductors, then the other lead is___.
A, connected to another conductor b, connected to the conduit or raceway c. Connected to a special grounding electrode on the megohmmeter d. Left unconnected
A(n) _________ is a reliable conductor used to ensure the required electrical conductivity between metal parts required to be electrically connected. a) Equipment bonding jumper b) Bonding conductor of jumper c) Main bonding jumper d) Equipment grounding conductor
If a grounding electrode conductor is connected at the first system disconnecting means or overcurrent device, the bonding jumper is sized the same as the ____.
Select one:
A. EQUIPMENT BONDING JUMPER
B. POSITIVE CONDUCTOR
C. SUPPLY-SIDE BONDING JUMPER
D. NEUTRAL CONDUCTOR
Chapter 16 Solutions
EBK ELECTRICAL WIRING RESIDENTIAL
Ch. 16 - Prob. 1RCh. 16 - What are the circuit ratings? __________________Ch. 16 - Prob. 3RCh. 16 - Prob. 4RCh. 16 - Prob. 5RCh. 16 - a. How many lights are recommended for a one-car...Ch. 16 - From how many points in the garage of this...Ch. 16 - GFCI breakers or GFCI receptacles are relatively...Ch. 16 - The total estimated volt-ampere load of the garage...Ch. 16 - Prob. 10R
Ch. 16 - Prob. 11RCh. 16 - Prob. 12RCh. 16 - In the spaces provided, fill in the cover (depth)...Ch. 16 - What section of the Code prohibits embedding Type...Ch. 16 - Prob. 15RCh. 16 - When a box-cover unit is installed for an overhead...Ch. 16 - When outdoor receptacles are installed where a...Ch. 16 - In order to wire a post light, a homeowner...Ch. 16 - What concerns are there when installing a...
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.Similar questions
- List the minimum trade size of Type EMT for each of the following applications. Assume the use of conductors with THHN insulation. Six 14 AWG ______ Six 12 AWG ______ Three 10 AWG ______ Four 8 AWG ______arrow_forward14. A grounded circuit conductor and the equipment grounding conductor should always be joined at theservice by aA. steel raceway.B. main bonding jumper.C. bus bar.D. short length of aluminum conductor.arrow_forwardEquipment Grounding 13. A metal elbow is a part of a nonmetallic, underground raceway. The elbow won't need to be grounded as long as it's encased in at least _______ inches of concrete. A. 4 B. 5 C. 2 D. 6 13 A. Which of the following can be in the form of a wire and is required to be installed with feeders and branch circuits? A. Phased neutral conductorB. Equipment grounding conductor C. Grounded neutral conductorD. Grounding electrode conductorarrow_forward
- What section of the Code prohibits supporting fire alarm conductors from raceways that contain light or power conductors? NEC ______.arrow_forwardAs permitted, installing cables of entirely nonmetallic sheaths into the top of a surface-mounted enclosure through one or more nonflexible raceways, the raceways shall be not less than ________ and not more than __________ in length, provided they meet all of the following conditions: Nonmetallic-sheathed cable secured within __________ in. from where it emerges from the raceway. The raceway comes out of the top of the enclosure and making sure it does not penetrate a ___________ . A fitting is needed at each end of the raceway, and it must remain accessible after the install in order to protect against _____________. Raceways must be _____________ or ___________ to prevent access into the enclosure through the raceway. The cable sheath must be ____________ and extend into the enclosure at least a _____________ in. The raceway must be _____________. When cable(s) are installed in raceways as mentioned above, what NEC Table and Chapter provide guidance on the cable fill require- ments…arrow_forwardTwo #12 THW copper conductors and one # 12 grounding conductor are pulled in a 49'-9" run of 3/4"conduit which is available in 10' lengths. How many pieces of conduit are required?arrow_forward
- 1)Restrictions on types of conduits used for installing service, sub panel, emergency service panel. 2Requirements for underground or overhead services. 3Type of protection requirements for raceways containing conductors (i.e.conductor sizes). 4Temperature correction factors associated with installation. 8. Voltagedropconsiderationsarrow_forwardExpansion fittings and telescoping sections of metal raceways shall be made electrically continuous by _____ or other means. Select one: A. GROUNDING ELECTRODE B. GROUNDED CURRENT CARRYING CONDUCTOR C. EQUIPMENT BONDING JUMPERarrow_forwardFill in the blank _______________ is possible because of the residual magnetism in the stator pole pieces.arrow_forward
- 6. Ferrous metal raceways or enclosures are made with _______ content.A. brass or aluminumB. steel or brassC. aluminum or ironD. iron or steelarrow_forwardQUESTION 3 We are running 3 wires and a ground in a RMC to a control panel with a 60 amp circuit breaker disconnect in the control panel. The conduit is run along the ceiling where the ambient air temperature is 100 degrees. The control panel feeds our secondary cooling pump. What size are the ungrounded conductors? All conductors have typeTHHN insulation.arrow_forward8. You're installing type AC cable. The armor coating of type AC cable is allowed for use as an equipmentgrounding conductor (EGC) because of itsA. liquid-tight fittings listed for EGC purposes.B. interlocking ribs that form a complete circuit.C. internal bare bonding strip.D. internal bare aluminum bonding conductor.arrow_forward
arrow_back_ios
SEE MORE QUESTIONS
arrow_forward_ios
Recommended textbooks for you
- EBK ELECTRICAL WIRING RESIDENTIALElectrical EngineeringISBN:9781337516549Author:SimmonsPublisher:CENGAGE LEARNING - CONSIGNMENT
EBK ELECTRICAL WIRING RESIDENTIAL
Electrical Engineering
ISBN:9781337516549
Author:Simmons
Publisher:CENGAGE LEARNING - CONSIGNMENT