Principles of Instrumental Analysis, 6th Edition
Principles of Instrumental Analysis, 6th Edition
6th Edition
ISBN: 9788131525579
Author: Douglas A. Skoog, F. James Holler, Stanley R. Crouch
Publisher: Cenage Learning
Question
Book Icon
Chapter 15, Problem 15.8QAP
Interpretation Introduction

(a)

Interpretation:

A working curve from the data should be constructed.

Concept introduction:

Standard addition method is used to analyze complex samples which matrix effect is significant. One common approach is standard addition technique is spiking of sample. In this method, one or more increments of a standard solution is added to the several aliquots of sample containing same volume. Each solution is then diluted to a fixed volume and experiment is proceeded.

Interpretation Introduction

(b)

Interpretation:

A linear least-squares equation for the data should be determined.

Concept introduction:

Syy=(yiy¯)2Sxx=(xix¯)2Sxy=(xix¯)(yiy¯)

The slope of the line, m=SxySxx

The intercept, b=y¯mx¯

Interpretation Introduction

(c)

Interpretation:

The standard deviation of the slope and intercept and the standard deviation about regression for the curve should be determined.

Concept introduction:

Standard deviation about regression, sr=Syym2SxxN2

N − number of points used.

The standard deviation of the slope, sm=sr2Sxx

The standard deviation of the intercept, sb=srxi2Nxi2(xi)2

Interpretation Introduction

(d)

Interpretation:

The concentration of Zn2+ in the sample should be calculated.

Concept introduction:

Standard addition method is used to analyze complex samples which matrix effect is significant. One common approach is standard addition technique is spiking of sample. In this method, one or more increments of a standard solution is added to the several aliquots of sample containing same volume. Each solution is then diluted to a fixed volume and experiment is proceeded.

Interpretation Introduction

(e)

Interpretation:

The standard deviation for the result in part (d) should be calculated.

Concept introduction:

Standard deviation of the results obtained from standard addition method = sc=Cx(smm)2+(sbb)2

M − number of replicates

N- number of calibration points.

Blurred answer
Students have asked these similar questions
Concentration (mg/l) Peak Area 0 158 10 10241 20 18425 30 26457 40 37125 50 44256 60 56124 You have been asked to determine the concentration of citral in a highly valued magnolia essential oil. QUESTION: Calculate the concentration of citral in your highly valued magnolia essential oil which returns a peak area of 41658
Need help with these problems...if you can please help me understand problems E & F.
Please help me solve these problems. Thank you in advance.
Knowledge Booster
Background pattern image
Similar questions
SEE MORE QUESTIONS
Recommended textbooks for you
Text book image
Fundamentals Of Analytical Chemistry
Chemistry
ISBN:9781285640686
Author:Skoog
Publisher:Cengage
Text book image
Principles of Instrumental Analysis
Chemistry
ISBN:9781305577213
Author:Douglas A. Skoog, F. James Holler, Stanley R. Crouch
Publisher:Cengage Learning
Text book image
Principles of Modern Chemistry
Chemistry
ISBN:9781305079113
Author:David W. Oxtoby, H. Pat Gillis, Laurie J. Butler
Publisher:Cengage Learning
Text book image
Macroscale and Microscale Organic Experiments
Chemistry
ISBN:9781305577190
Author:Kenneth L. Williamson, Katherine M. Masters
Publisher:Brooks Cole