a)
The rate of heat transfer of air stream.
a)

Answer to Problem 83P
The rate of heat transfer of air stream is
Explanation of Solution
Write the expression to obtain the vapor pressure of air
Here, saturated pressure is
Write the expression to obtain the atmospheric pressure of an ideal gas mixture
Here, vapor pressure at state 1 is
Write the expression to obtain the specific volume of circular duct
Here, inlet temperature is
Write the expression to obtain the specific humidity
Write the expression to obtain the enthalpy at state 1
Here, specific heat of air is
Write the expression to obtain the exit vapor pressure of air
Here, saturated pressure is
Write the expression to obtain the atmospheric pressure of an ideal gas mixture
Here, vapor pressure at state 2 is
Write the expression to obtain the specific volume of circular duct
Here, final temperature is
Write the expression to obtain the specific humidity
Write the expression to obtain the enthalpy at state 2
Here, specific heat of air is
Write the expression to obtain the volume flow rate
Here, diameter is D, and velocity of air is
Write the expression to obtain the mass flow rate of dry air through the cooling section
Here, volume flow rate of air entering the cooling section is
Apply the water mass balance equation to the combined cooling and dehumidification section.
Here, initial and final mass flow rate of dry air is
Apply the water energy balance equation to the combined cooling and dehumidification section.
Here, the amount of energy rate required for cooling coils is
Conclusion:
Refer Table A-4E, “Saturated water – Temperature table”, write the value of saturation pressure of liquid
Substitute 0.69904 psia for
Refer Table A-5E, “Saturated water – Temperature table”, obtain the properties of water at a temperature of
Rewrite Equation (II) and substitute 14.4 psia for
Convert the unit of
Refer the Table “Ideal gas specific heats of various common gases”, write the value of
Substitute
The mass flow rate of dry air remains constant, but the amount of moisture in the air decreases due to the dehumidification
Substitute 0.42 psia for
Refer Table A-4E, “Saturated water – Temperature table”, write the value of
Refer the Table “Ideal gas specific heats of various common gases”, write the value of
Substitute
Refer Table A-4E, “Saturated water – Temperature table”, write the value of saturated pressure
Substitute 0.36 psia for
Rewrite Equation (VII) and substitute 14.4 psia for
Convert the unit of
Substitute
Substitute 0.36 psia for
Refer Table A-4E, “Saturated water – Temperature table”, write the value of
Substitute
Refer Table A-4E, “Saturated water – Temperature table”, write the value of enthalpy at saturation liquid
Substitute 1 ft for D and
Substitute
Substitute
Substitute
Thus, rate of heat transfer of air stream is
b)
The mass flow rate of cooling water.
b)

Answer to Problem 83P
The mass flow rate of cooling water is
Explanation of Solution
Write the expression to obtain the mass flow rate of cooling water
Here, specific heat of water is
Conclusion:
Substitute
Thus, the mass flow rate of cooling water is
c)
The exit velocity of the airstream.
c)

Answer to Problem 83P
The exit velocity is
Explanation of Solution
Apply the conservation of mass of dry air to calculate exit velocity
Conclusion:
Substitute
Thus, the exit velocity is
Want to see more full solutions like this?
Chapter 14 Solutions
EBK THERMODYNAMICS: AN ENGINEERING APPR
- Air enters the compressor of a regenerative gas turbine engine at 310 K and 100 kPa, where it is compressed to 900 kPa and 650 K. The regenerator has an effectiveness of 75%, and the air enters the turbine at 1400 K. Assume variable specific heats for air. For a turbine efficiency of 90 percent, determine the amount of heat transfer in the regenerator. The amount of heat transfer in the regenerator is kJ/kg.arrow_forwardAir enters the compressor of a regenerative gas turbine engine at 310 K and 100 kPa, where it is compressed to 900 kPa and 650 K. The regenerator has an effectiveness of 79 percent, and the air enters the turbine at 1400 K. Assume constant specific heats for air at room temperature. The properties of air at room temperature are cp = 1.005 kJ/kg·K and k = 1.4. For a turbine efficiency of 90 percent, determine the amount of heat transfer in the regenerator. The amount of heat transfer in the regenerator is kJ/kg.arrow_forwardHints: Find the closed loop transfer function and then plot the step response for diFerentvalues of K in MATLAB. Show step response plot for different values of K. Auto Controls Show solutions and provide matlab code NO COPIED ANSWERS OR WILL REPORT!!!! Use own solutionarrow_forward
- what is shear stress and normal? how to tell them while calculating?arrow_forward12 mm 45 mm 20 kN 20 kN 12 mm 45 mm PROBLEM 1.61 For the assembly and loading of Problem 1.60, determine (a) the average shearing stress in the pin at C, (b) the average bearing stress at C in member BC, (c) the average bearing stress at B in member BC. PROBLEM 1.60 Two horizontal 20-kN forces are applied to pin B of the assembly shown. Knowing that a pin of 20-mm diameter is used at each connection, determine the maximum value of the average normal stress (a) in link AB, (b) in link BC.arrow_forwardHow do you find these answers?arrow_forward
- 250 mm 400 mm A B C E F 250 mm PROBLEM 1.52 Each of the two vertical links CF connecting the two horizontal members AD and EG has a 10 × 40-mm uniform rectangular cross section and is made of a steel with an ultimate strength in tension of 400 MPa, while each of the pins at C and F has a 20-mm diameter and are made of a steel with an ultimate strength in shear of 150 MPa. Determine the overall factor of safety for the links CF and the pins connecting them to the horizontal members. 24 kNarrow_forward50 mm 12 mm B O C OA 300 mm 450 mm E PROBLEM 1.51 Each of the steel links AB and CD is connected to a support and to member BCE by 25-mm-diameter steel pins acting in single shear. Knowing that the ultimate shearing stress is 210 MPa for the steel used in the pins and that the ultimate normal stress is 490 MPa for the steel used in the links, determine the allowable load P if an overall factor of safety of 3.0 is desired. (Note that the links are not reinforced around the pin holes.)arrow_forward3. A 15% magnesium chloride solution is flowing through a 5-nom sch 40 commercial steel pipe at a rate of 325,000 lbm/h. The average temperature of the magnesium chloride solution as it flows through the pipe is 10°F. Determine the convective heat transfer coefficient inside the pipe.arrow_forward
- Elements Of ElectromagneticsMechanical EngineeringISBN:9780190698614Author:Sadiku, Matthew N. O.Publisher:Oxford University PressMechanics of Materials (10th Edition)Mechanical EngineeringISBN:9780134319650Author:Russell C. HibbelerPublisher:PEARSONThermodynamics: An Engineering ApproachMechanical EngineeringISBN:9781259822674Author:Yunus A. Cengel Dr., Michael A. BolesPublisher:McGraw-Hill Education
- Control Systems EngineeringMechanical EngineeringISBN:9781118170519Author:Norman S. NisePublisher:WILEYMechanics of Materials (MindTap Course List)Mechanical EngineeringISBN:9781337093347Author:Barry J. Goodno, James M. GerePublisher:Cengage LearningEngineering Mechanics: StaticsMechanical EngineeringISBN:9781118807330Author:James L. Meriam, L. G. Kraige, J. N. BoltonPublisher:WILEY