To determine

Find the amount of natural gas required in ft3 and lbm for generating for electricity for each year.

Expert Solution & Answer
Check Mark

Answer to Problem 19P

The amount of natural gas required in ft3 and lbm for generating for electricity for each year is calculated and tabulated in Table 1.

Explanation of Solution

Given data:

Refer to problem 13-19 accompanying table in the textbook.

The average efficiency of the power plant is 35%.

The heating value of the natural gas is 1000Btuft3(22000Btulbm).

Formula used:

Formula to calculate the power plant efficiency is,

Powerplanteffeicency=EnergygeneratedEnergyinputfromfuel

Rearrange the equation,

Energyinputfromfuel=Energygeneratedpowerplanteffeicency (1)

Convert Btu to lbm,

1Btu=122000lbm[22000Btulbm=1]=4.5454×105lbm (2)

Convert lbm to ft3,

1000Btuft3=22000Btulbm10001ft3=220001lbm1ft3=221lbm1lbm=22ft3 (3)

The value of the 1Btus is,

1Btus=1.055kW (4)

Convert 1 hr into seconds,

1hr=3600s

Rearrange the equation,

1s=13600hr (5)

Substitute equation (5) in equation (4),

1Btu13600hr=1.055kW1Btu=1.0553600kWhr1Btu=2.93×104kWhr

Rearrange the equation,

1kWhr=12.93×104Btu=3412.96Btu

Calculation:

Converting the given data from kWh to Btu:

Substitute 3412.96Btu for 1kWhr in 346.2399×109kWhr for the year 1980,

346.2399×109kWhr=(346.2399×109)(3412.96Btu)=1.181702929×1015Btu=1181702.929×109Btu

Substitute 3412.96Btu for 1kWhr in 372.7652×109kWhr for the year 1990,

372.7652×109kWhr=(372.7652×109)(3412.96Btu)=1.272232717×1015Btu=1272232.717×109Btu

Substitute 3412.96Btu for 1kWhr in 601.0382×109kWhr for the year 2000,

601.0382×109kWhr=(601.0382×109)(3412.96Btu)=2.051319335×1015Btu=2051319.335×109Btu

Substitute 3412.96Btu for 1kWhr in 751.8189×109kWhr for the year 2005,

751.8189×109kWhr=(751.8189×109kWhr)(3412.96Btu)=2.565927833×1015Btu=2565927.833×109Btu

Substitute 3412.96Btu for 1kWhr in 773.8234×109kWhr for the year 2010,

773.8234×109kWhr=(773.8234×109)(3412.96Btu)=2.641028311×1015Btu=2641028.311×109Btu

Substitute 3412.96Btu for 1kWhr in 1102.762×109kWhr for the year 2020,

1102.762×109kWhr=(1102.762×109)(3412.96Btu)=3.763682596×1015Btu=3763682.596×109Btu

Substitute 3412.96Btu for 1kWhr in 992.7706×109kWhr for the year 2030,

992.7706×109kWhr=(992.7706×109)(3412.96Btu)=3.388286347×1015Btu=3388286.347×109Btu

Now find the energy input fuel for each year in Btu for natural gas:

Substitute 1181702.929×109Btu for energy generated and 0.35 for power plant efficiency in equation (1) to find energy input from fuel in 1980,

Energyinputfromfuel=1181702.929×109Btu0.35=3.376294083×1015BtuEnergyinputfromfuel=3376294.083×109Btu

Substitute 1272232.717×109Btu for energy generated and 0.35 for power plant efficiency in equation (1) to find energy input from fuel 1990,

Energyinputfromfuel=1272232.717×109Btu0.35=3.63495062×1015BtuEnergyinputfromfuel=3634950.62×109Btu

Substitute 2051319.335×109Btu for energy generated and 0.35 for power plant efficiency in equation (1) to find energy input from fuel 2000,

Energyinputfromfuel=2051319.335×109Btu0.35=5.860912386×1015BtuEnergyinputfromfuel=5860912.386×109Btu

Substitute 2565927.833×109Btu for energy generated and 0.35 for power plant efficiency in equation (1) to find energy input from fuel 2005,

Energyinputfromfuel=2565927.833×109Btu0.35=7.33122238×1015BtuEnergyinputfromfuel=7331222.38×109Btu

Substitute 2641028.311×109Btu for energy generated and 0.35 for power plant efficiency in equation (1) to find energy input from fuel 2010,

Energyinputfromfuel=2641028.311×109Btu0.35=7.545795174×1015BtuEnergyinputfromfuel=7545795.174×109Btu

Substitute 3763682.596×109Btu for energy generated and 0.35 for power plant efficiency in equation (1) to find energy input from fuel 2020,

Energyinputfromfuel=3763682.596×109Btu0.35=1.075337885×1016BtuEnergyinputfromfuel=10753378.85×109Btu

Substitute 3388326.347×109Btu for energy generated and 0.35 for power plant efficiency in equation (1) to find energy input from fuel 2030,

Energyinputfromfuel=3388286.347×109Btu0.35=9680818.134×109Btu

Now convert Btu to lbm as follows by using the relation 1Btu=4.5454×105lbm,

Substitute 4.5454×105lbm for 1 Btu in 3376294.083×109Btu for the year 1980,

3376294.083×109Btu=(3376294.083×109)(4.5454×105lbm)=1.5346607×1011lbm1.53×1011lbm

Substitute 4.5454×105lbm for 1 Btu in 3634950.62×109Btu for the year 1990,

3634950.62×109Btu=(3634950.62×109)(4.5454×105lbm)=1.652230×1011lbm1.65×1011lbm

Substitute 4.5454×105lbm for 1 Btu in 5860912.386×109Btu for the year 2000,

5860912.386×109Btu=(5860912.386×109)(4.5454×105lbm)=2.664019×1011lbm2.66×1011lbm

Substitute 4.5454×105lbm for 1 Btu in 7331222.38×109Btu for the year 2005,

7331222.38×109Btu=(7331222.38×109)(4.5454×105lbm)=3.3323×1011lbm3.33×1011lbm

Substitute 4.5454×105lbm for 1 Btu in 7545795.174×109Btu for the year 2010,

7545795.174×109Btu=(7545795.174×109)(4.5454×105lbm)=3.429865×1011lbm3.43×1011lbm

Substitute 4.5454×105lbm for 1 Btu in 10753378.85×109Btu for the year 2020,

10753378.85×109Btu=(10753378.85×109)(4.5454×105lbm)=4.88784×1011lbm4.89×1011lbm

Substitute 4.5454×105lbm for 1 Btu in 9680818.134×109Btu for the year 2030,

9680818.134×109Btu=(9680818.134×109)(4.5454×105lbm)=4.4003190×1011lbm4.40×1011lbm

Now convert Form lbm to ft3 by using the relation 1lbm=22ft3 as follows,

Substitute 22ft3 for 1 lbm in 1.5346607×1011lbm for the year 1980,

1.5346607×1011lbm=(1.5346607×1011)(22ft3)=3.37625×1012ft33.38×1012ft3

Substitute 22ft3 for 1 lbm in 1.652230×1012lbm for the year 1990,

1.652230×1011lbm=(1.652230×1011)(22ft3)=3.6354906×1012ft33.63×1012ft3

Substitute 22ft3 for 1 lbm in 2.664019×1012lbm for the year 2000,

2.664019×1011lbm=(2.664019×1011)(22ft3)=5.8608418×1012ft35.86×1012ft3

Substitute 22ft3 for 1 lbm in 3.33233×1010lbm for the year 2005,

3.33233×1011lbm=(3.33233×1011)(22ft3)=7.331126×1012ft37.33×1012ft3

Substitute 22ft3 for 1 lbm in 3.429865×1011lbm for the year 2010,

3.429865×1011lbm=(3.429865×1011)(22ft3)=7.545703×1012ft37.55×1012ft3

Substitute 22ft3 for 1 lbm in 4.88784×1011lbm for the year 2020,

4.88784×1011lbm=(4.88784×1011)(22ft3)=1.0753358×1013ft31.08×1013ft3

Substitute 22ft3 for 1 lbm in 4.400319×1011lbm for the year 2030,

4.400319×1011lbm=(4.400319×1011)(22ft3)=9.6807018×1012ft39.68×1012ft3

Therefore, the amount of natural gas in ft3 and lbm for generating electricity for each year required is tabulated as in Table 1 with approximately rounded values for amount of natural gas needed in lbm and amount of natural gas needed in ft3.

Engineering Fundamentals: An Introduction to Engineering (MindTap Course List), Chapter 13, Problem 19P

Conclusion:

Hence, the amount of natural gas in ft3 and lbm for generating electricity for each year has been calculated.

Want to see more full solutions like this?

Subscribe now to access step-by-step solutions to millions of textbook problems written by subject matter experts!
Students have asked these similar questions
Note: Provide a clear, step-by-step handwritten solution (without any detailed explanations). Ensure the work is simplified and completed manually, adhering to expert-level accuracy. Refer to the provided image for clarity and ensure all calculations are double-checked for correctness before submission. Thank you!.   Question 1:  A cylindrical soil sample is connected to two water reservoirs: a) Determine the pressure, elevation, and total head at a point one meter above the bottom of the sample (point A). b) Calculate the pore pressure and effective stress at point A if the soil has a saturated unit weight of 18.7kN/m^3. c) Determine the water flow rate though the sample if the soil has a coefficient of permeability of 0.19 cm/s and the radius of the sample is 20 mm. d) Is it possible for the soil to reach the “quick condition”(zero effective stress) by raising the level of the water in the upper reservoir? Why or why not?. Question 2: A new structure is planned to be constructed in…
Note: Provide a clear, step-by-step, simplified handwritten solution (no explanations), ensuring it is completed without any AI involvement. The solution must demonstrate expert-level accuracy and will be evaluated for its quality and precision. Please refer to the provided image for additional clarity. Double-check all calculations for correctness before submission. Thank you!. Question 1: (refer to the image for visual understanding) For the soil element shown on the right: a) Draw the Mohr’s circle for this case  b) Find the major and minor principal stresses  c) Find the normal and shear stresses on plane AB. Question 2:  (refer to the image) A soil sample in a triaxial test with a cell pressure of 100 kPa fails when the vertical stress reaches 400 kPa. The resulting failureplane is observed to dip 60 degrees from horizontal (see figure). Assume that the soil is drained during the test, i.e. there is no pore pressure. a) Determine the friction angle of the soil. Hint: draw the…
Please solve all points
Knowledge Booster
Background pattern image
Civil Engineering
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, civil-engineering and related others by exploring similar questions and additional content below.
Similar questions
SEE MORE QUESTIONS
Recommended textbooks for you
Text book image
Engineering Fundamentals: An Introduction to Engi...
Civil Engineering
ISBN:9781305084766
Author:Saeed Moaveni
Publisher:Cengage Learning
Text book image
Sustainable Energy
Civil Engineering
ISBN:9781337551663
Author:DUNLAP, Richard A.
Publisher:Cengage,
Text book image
Sustainable Energy
Civil Engineering
ISBN:9781133108689
Author:Richard A. Dunlap
Publisher:Cengage Learning