Residential Construction Academy: House Wiring (MindTap Course List)
4th Edition
ISBN: 9781285852225
Author: Gregory W Fletcher
Publisher: Cengage Learning
expand_more
expand_more
format_list_bulleted
Concept explainers
Question
Chapter 12, Problem 6RQ
To determine
The article of the NEC covering Type EMT
Expert Solution & Answer
Want to see the full answer?
Check out a sample textbook solutionStudents have asked these similar questions
1. A 150 X 90 X 12 mm angular
section is welded to a gusset
plate shown.
Area of angular section is 2376
sq.mm.
Fu = 550 MPa
Allowable shear Fv=0.30FU
Fy = 250 MPa
Allowable tensile stress Ft =
0.60FY
a. Determine the force P
b. Determine the total length of
weld using 12mm fillet weld
c. Determine the value of a
d. Determine the value of b
wo.t
2-22 mm
(n.)
2-22mm
(d,)
3-22mm
(f)
12m-
23cm
8cm
w 8.1
38 cm.
P.L
40cm
بسته
09-
cm
2.6 m
23-22mm
(2)
-1.22mm (h)
1-22mm)
-1-37m
10mm STPS.
@12mm c/c
-21mx18m
2.1m
L38
cm
25 mm CLEAR.
COVER
3-22 mm (c)
-6-22 mm (d)
-30 cm
-6-22mm (c)
38
cm
SECTION-1-1
10 mm
105
-2-22m.
-2-22 mm STRAIGHT 2
IX
-3-22 mm (f)
PLAN OF 38 cm x 25cm. COLN.
25-22mm (4.h. i)
-10 mm STPS @25cm
-5.5m
BINDER
23 cm
3-22 mm
(c)
1-22 mm.
(8)
10mm
STIRRUPS-
-22 mm
@9 cm c/c (0)
-22 mm @ 9cm c/c (b)
-20 NOS. RODS (LONG SIDE)
17 NOS RODS (SHORT SIDE)
2
-1.37m-
-/4-18mm STR
12 cmc/c
-5-22 mm
(disf)
-4-22mm
(h. i)
125
cm
SECTION 2-2
-50mm CLEAR COVER
-8 cm LEAN CONC. (1:4:8)novations
38
-Prepare a complete schedule of bars of the portal frame as shown in the
4-15. Assume weight of 22mbar-2-98 kg/rm and 10mm bar-0.62 kg/rm.
Twar
469
Chapter 12 Solutions
Residential Construction Academy: House Wiring (MindTap Course List)
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, civil-engineering and related others by exploring similar questions and additional content below.Similar questions
- Small-appliance branch circuits and laundry branch circuits installed in a dwelling must have a rating of at least__________ amperes. This information is found in NEC Section __________. (Objective 6-2)arrow_forwardName the ampacity for the following copper conductors according to Table 310.15(B) (16): (Objective 6-4) a. 10 AWG THW amps _____ amps b. 8 AWG THWN amps_______ amps c. 1 AWG THHN amps ______ amps d. 4/0 TW amps ______ ampsarrow_forwardDirections: Circle T to indicate true statements or F to indicate false statements. The higher the resistance in an electrical circuit, the lower the amount of current that can flow in the circuit. (Objective 1-2)arrow_forward
- If Type SER service entrance cable is used by an electrician to feed a subpanel from a main panel, the cable must be secured within _________of the panel enclosures and at Intervals not exceeding___________. Name the NEC section that states this requirement. (Objective 8-7)arrow_forwardA wall-mounted luminaire (fixture) weighing not more than_________ pounds is permitted to be supported on a device box provided the luminaire or its supporting yoke is secured to the box with no fewer than two 6-32 or Larger screws. Name the NEC section that covers this requirement. (Objective 9-5)arrow_forwardExplain the difference between new-work and old-work electrical boxes. (Objective 10-1)arrow_forward
- The metal frame of a switch or receptacle is called a (n) ______ or ______. (Objective 18-3)arrow_forwardName the tool used to remove cartridge fuses from an electrical enclosure. (Objective 3-2)arrow_forwardIn a work situation where an electricians hands get wet while operating a 120-volt, corded drill, which of the following would be true? (Objective 1-1) a. Body resistance increases, and any shock would be mild. b. Body resistance remains the same, and there is no danger as Long as rubber boots are worn. c. Body resistance is substantially decreased, and severe shock could occur. d. There is no danger as Long as a three-prong plug is used.arrow_forward
- The most often used category-rated UTP cable for voice and data wiring from various outlets back to the service center or other distribution device in a residential application is______. (Objective 16-3)arrow_forwardDescribe when an electrician would use a new work box and an old work box. (Objective 2-3)arrow_forward
arrow_back_ios
arrow_forward_ios
Recommended textbooks for you
- Residential Construction Academy: House Wiring (M...Civil EngineeringISBN:9781337402415Author:Gregory W FletcherPublisher:Cengage Learning
Residential Construction Academy: House Wiring (M...
Civil Engineering
ISBN:9781337402415
Author:Gregory W Fletcher
Publisher:Cengage Learning