EBK ELECTRICAL WIRING RESIDENTIAL
EBK ELECTRICAL WIRING RESIDENTIAL
19th Edition
ISBN: 9781337516549
Author: Simmons
Publisher: CENGAGE LEARNING - CONSIGNMENT
bartleby

Concept explainers

Question
Book Icon
Chapter 12, Problem 25R

a.

To determine

Check whether the given statement is true or false.

b.

To determine

Check whether the given statement is true or false.

Blurred answer
Students have asked these similar questions
21.Which of the following wiring methods may be used inside the duct used for vapor removal and ventilation of commercial type cooking equipment?  (a.) nonmetallic sheathed cable (b.) EMT (c.) rigid steel conduit (d.) none of these   22. Ground-fault circuit-interrupter (GFCI) protection is required in all of the following locations EXCEPT: (a.) kitchen receptacles in an office building lunchroom installed within 6’ of the sink  (b.) kitchen receptacles in a dwelling installed to serve counter top surfaces 10’ away from the sink  (c.) receptacles in an office building restroom which has only a basin and toilet (d.) receptacle provided for servicing a rooftop air conditioning unit on the roof of a warehouse   23. Where GFCI protection is located in the power supply cord for an outdoor portable sign, the ground-fault circuit interrupter shall be located within _____inches of the attachment plug. (a.) 6 (c.) 18 (b.) 12 (d.) 24
5. If a separate, wire-type equipment grounding conductor (EGC) is used for any reason, the EGC of a grounding-type receptacle must be connected to which of the following?A. The grounding terminal bar outside the service equipment enclosure in a grounded systemB. An EGC that's part of another branch circuit that originates from where the branch circuit for the receptacle originatesC. Any accessible point on the grounding electrode conductorD. The service conductor outside the service equipment enclosure in an ungrounded system
5.a. Typically, the bonding conductor installed between the panelboard equipment grounding terminal barsmust be continuous. It's only allowed to be broken where it connects to theA. signal reference grid.B. terminal bar in the panelboard.C. branch circuit.D. service entrance enclosure.5.b. An electrical system that's not grounded and is between 120 and 1000 volts must include the use ofA. arc suppression.B. ground isolators.C. ground detectors.D. equipotential barriers.
Knowledge Booster
Background pattern image
Electrical Engineering
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.
Similar questions
SEE MORE QUESTIONS
Recommended textbooks for you
Text book image
EBK ELECTRICAL WIRING RESIDENTIAL
Electrical Engineering
ISBN:9781337516549
Author:Simmons
Publisher:CENGAGE LEARNING - CONSIGNMENT