The person responsible for using metal or nonmetallic electrical boxes in a house.
Explanation of Solution
The electrical contractor decides whether it is necessary to install non-metallic electrical boxes or metal electrical boxes in a house during the process of wiring.
When an electrician goes through the electrical plan, the particular electrical box to be mounted at a place in the house will be determined by him. Some
Conclusion:
The electrical contractor determines whether metal or nonmetal electrical boxes will be used in the house.
Want to see more full solutions like this?
Chapter 10 Solutions
Residential Construction Academy: House Wiring (MindTap Course List)
- Describe the purpose of an LB conduit body used in a residential service entrance Installation that uses electrical conduit. (Objective 8-1)arrow_forwardDescribe how a conductor that is larger than 6 AWG can be identified as a grounding conductor. Name the NEC section that covers this wiring situation. (Objective 9-4)arrow_forwardName the three styles of screwdrivers used most often in residential electrical work. (Objective 3-1)arrow_forward
- Describe when an electrician would use a new work box and an old work box. (Objective 2-3)arrow_forwardExplain the difference between new-work and old-work electrical boxes. (Objective 10-1)arrow_forwardThe minimum amount of free conductor required at an electrical box used in residential wiring for termination purposes is______________ inches. As long as the box has no dimension Larger than 8 Inches (200 mm), there must be at Least ______ inches of free conductor extending out from the box opening. Name the NEC section that covers this wiring practice. (Objective 9-3)arrow_forward
- List the minimum trade size of Type EMT for each of the following applications. Assume the use of conductors with THHN insulation. (Objective 12-1) a. Six 14 AWG _______ b. Six 12 AWG ______ c. Three 10 AWG ______ d. Four 8 AWG _____arrow_forwardDirections: Answer the following items with clear and complete responses. Calculate the minimum copper conductor size needed for a 120/240-volt electric range branch circuit. The electric range has a nameplate rating of 12 kW. Show all work.arrow_forwardCalculate the minimum copper conductor size needed for a 120/240-volt electric range branch circuit. The electric range has a nameplate rating of 12 kW. Show all work. (Objective 6-2)arrow_forward