Electrical Wiring: Residental - With Plans (Paperback) Package
Electrical Wiring: Residental - With Plans (Paperback) Package
18th Edition
ISBN: 9781305416376
Author: MULLIN
Publisher: Cengage
bartleby

Concept explainers

Question
100%
Book Icon
Chapter 10, Problem 1R
To determine

Name the types of receptacles and switches, and mention the number of receptacles and switches that are used in circuit A14.

Expert Solution & Answer
Check Mark

Answer to Problem 1R

The types of switches and receptacles used in circuit A14 are listed, and totally four switches and one receptacle are used in circuit A14.

Explanation of Solution

Discussion:

Circuit A14 is a 15-ampere branch circuit that delivers power to the hallway receptacle, the hallway lighting, and the vanity lighting used in bathrooms.

The types of switches and receptacles used in the hallway and bathrooms (Circuit A14) are listed as follows:

  • • One receptacle in the hall.
  • • One single-pole switch in the hall bathroom.
  • • One single-pole switch in the master bathroom.
  • • Two 3-way switches in the hall.

Therefore, from the above list, totally four switches and one receptacle are used in the hallway and bathrooms. Hence, a total of five numbers are used in Circuit A14.

Refer to NEC 210.11(C)(3), the receptacles used in the bathrooms are supplied by separate 20-ampere branch circuits A22 and A23.

Conclusion:

Thus, the types of switches and receptacles used in circuit A14 are listed, and totally four switches and one receptacle are used in circuit A14.

Want to see more full solutions like this?

Subscribe now to access step-by-step solutions to millions of textbook problems written by subject matter experts!
Students have asked these similar questions
Calculate the assigned values in the circuits below.       E2 = ________            E3 = _________          E6 = _________          E9 = _________ E11 = ________           E13 = _________         RT = ________            R6 = __________ IT = _________           I5   = __________        I7 = _________           I10 = __________ PT = ________
Follow the procedures in troubleshooting the defects and faults of an electric fan by filling in the missing steps.Doesn't rotate 1.___________ 2.____________ Check for Open AC cord or wiring3. ___________4.___________ Defective switch/electronic system control 5. _____________Defective module (system control).​
1. A14/2 type copper used for a general lighting branch circuit.                                                Ampacity:______________              Maximum Fuse or Circuit Breakers Sizes:________________      2.Three 8 AWG copper conductors with THHN insulation Installed in garage in electrical metallic tubing (EMT). The ambient temperature in the garage can reach as high as 110'F. All termination points for this circuit are rated 60'C.                            Ampacity:______________                  Maximum Fuse or Circuit Breakers Sizes:________________ 3.Four 4 AWG copper conductor with THWN insulation imstalled in EMT in a basement. All termination points are rated at 60'C.                                 Ampacity:______________                  Maximum Fuse or Circuit Breakers Sizes:________________  4. An 8/3 Type UF copper cable installed underground from a house to a detached garage to feed a 120/240-volt subpanel. All termination points are rated at 60'C.…
Knowledge Booster
Background pattern image
Electrical Engineering
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.
Similar questions
SEE MORE QUESTIONS
Recommended textbooks for you
Text book image
EBK ELECTRICAL WIRING RESIDENTIAL
Electrical Engineering
ISBN:9781337516549
Author:Simmons
Publisher:CENGAGE LEARNING - CONSIGNMENT