You are assigned to monitor the operation of water tank for the ABC company during your intemship placement. It is assumed that the water discharged from the tank should follow the discharge model f(x) = e*-1 - CA + B), where x is the pressure applied in Pascal (Pa) and f(x) is the amount of water discharged in m³ from the tank per-hour. The tank will need to undergo maintenance if the water discharge from the tank deviates at the true percent relative error of 5% from the discharge model. (The constants A and B are determined by the last two digits of your student's ID. For example: If your student's ID is 123456. A = 6 and B = 5. However, if your last two digits are 00 or 01 or 10, use A = 2 and B = 3.) Fill in TABLE Q3 with reasonable reading from your monitoring job, 7 < f(x) < 27. TABLE Q3 x (Pa) 3.5 3.7 3.9 4.1 4.3 f(x) (m³ /h) In the fulfillment of your internship completion, you are required to provide the performance report of the water tank, to suggest if maintenance is necessary. Your report should contain the error analysis of the machine performance against the discharge model. To validate reliabilities, your report must use all the readings from TABLE Q3 in each of your analysis, with 5 decimal places, and up to five iterations when necessary. The report should include the following. i. Estimation of water discharged when pressure of 3.8 Pa is used. i. Rate of production at the pressure of 3.9 Pa. ii. The suggested pressure if the water discharged is 15 m³/h. iv. Discussion of your analysis and suggestion if the maintenance is necessary.
You are assigned to monitor the operation of water tank for the ABC company during your intemship placement. It is assumed that the water discharged from the tank should follow the discharge model f(x) = e*-1 - CA + B), where x is the pressure applied in Pascal (Pa) and f(x) is the amount of water discharged in m³ from the tank per-hour. The tank will need to undergo maintenance if the water discharge from the tank deviates at the true percent relative error of 5% from the discharge model. (The constants A and B are determined by the last two digits of your student's ID. For example: If your student's ID is 123456. A = 6 and B = 5. However, if your last two digits are 00 or 01 or 10, use A = 2 and B = 3.) Fill in TABLE Q3 with reasonable reading from your monitoring job, 7 < f(x) < 27. TABLE Q3 x (Pa) 3.5 3.7 3.9 4.1 4.3 f(x) (m³ /h) In the fulfillment of your internship completion, you are required to provide the performance report of the water tank, to suggest if maintenance is necessary. Your report should contain the error analysis of the machine performance against the discharge model. To validate reliabilities, your report must use all the readings from TABLE Q3 in each of your analysis, with 5 decimal places, and up to five iterations when necessary. The report should include the following. i. Estimation of water discharged when pressure of 3.8 Pa is used. i. Rate of production at the pressure of 3.9 Pa. ii. The suggested pressure if the water discharged is 15 m³/h. iv. Discussion of your analysis and suggestion if the maintenance is necessary.
Related questions
Question
A is 9 B is 8
I just need to know how to calculate ii. Rate of production at the pressure of 3.9 Pa. WITH EXPLANATION!! THANK YOU
Expert Solution
This question has been solved!
Explore an expertly crafted, step-by-step solution for a thorough understanding of key concepts.
Step by step
Solved in 2 steps