with a subtransient reactance of 0.1 pu, are connected through a line of reactance 0.1 pu on the base of the machines rating. One machine is acting as a synchronous generator, while the other is working as a motor drawing 45-MW at 0.80 PF leading with a terminal voltage 14.5-kV. A symmetrical three-phase fault occurs at the motor bus. 21. The generator fault current contribution (p.u.) is most nearly; А. 4.37 В. 8.21 С. 14.50 D. 16.56 22. The motor fault current contribution (p.u.) is most nearly; A. 8.21 В. 10.21 С. 14.50 D. 16.56 23. The total fault current is most nearly А. 4.37 В. 10.21 С. 14.50 D. 16.5

Introductory Circuit Analysis (13th Edition)
13th Edition
ISBN:9780133923605
Author:Robert L. Boylestad
Publisher:Robert L. Boylestad
Chapter1: Introduction
Section: Chapter Questions
Problem 1P: Visit your local library (at school or home) and describe the extent to which it provides literature...
icon
Related questions
Question

Just Multiple choice.

Problem 4 (Questions 21 through 23)-Two identical synchronous machines, each rated 60– MVA,15– kV .
with a subtransient reactance of 0.1 pu, are connected through a line of reactance 0.1 pu on the base of the
machines rating. One machine is acting as a synchronous generator, while the other is working as a motor
drawing 45-MW at 0.80 PF leading with a terminal voltage 14.5-kV. A symmetrical three-phase fault occurs at
the motor bus.
21. The generator fault current contribution (p.u.) is most nearly;
А. 4.37
В. 8.21
С. 14.50
D. 16.56
22. The motor fault current contribution (p.u.) is most nearly;
A. 8.21
В. 10.21
С. 14.50
D. 16.56
23. The total fault current is most nearly
А. 4.37
В. 10.21
С. 14.50
D. 16.5
Transcribed Image Text:Problem 4 (Questions 21 through 23)-Two identical synchronous machines, each rated 60– MVA,15– kV . with a subtransient reactance of 0.1 pu, are connected through a line of reactance 0.1 pu on the base of the machines rating. One machine is acting as a synchronous generator, while the other is working as a motor drawing 45-MW at 0.80 PF leading with a terminal voltage 14.5-kV. A symmetrical three-phase fault occurs at the motor bus. 21. The generator fault current contribution (p.u.) is most nearly; А. 4.37 В. 8.21 С. 14.50 D. 16.56 22. The motor fault current contribution (p.u.) is most nearly; A. 8.21 В. 10.21 С. 14.50 D. 16.56 23. The total fault current is most nearly А. 4.37 В. 10.21 С. 14.50 D. 16.5
Expert Solution
trending now

Trending now

This is a popular solution!

steps

Step by step

Solved in 3 steps with 2 images

Blurred answer
Knowledge Booster
h and g parameter
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.
Recommended textbooks for you
Introductory Circuit Analysis (13th Edition)
Introductory Circuit Analysis (13th Edition)
Electrical Engineering
ISBN:
9780133923605
Author:
Robert L. Boylestad
Publisher:
PEARSON
Delmar's Standard Textbook Of Electricity
Delmar's Standard Textbook Of Electricity
Electrical Engineering
ISBN:
9781337900348
Author:
Stephen L. Herman
Publisher:
Cengage Learning
Programmable Logic Controllers
Programmable Logic Controllers
Electrical Engineering
ISBN:
9780073373843
Author:
Frank D. Petruzella
Publisher:
McGraw-Hill Education
Fundamentals of Electric Circuits
Fundamentals of Electric Circuits
Electrical Engineering
ISBN:
9780078028229
Author:
Charles K Alexander, Matthew Sadiku
Publisher:
McGraw-Hill Education
Electric Circuits. (11th Edition)
Electric Circuits. (11th Edition)
Electrical Engineering
ISBN:
9780134746968
Author:
James W. Nilsson, Susan Riedel
Publisher:
PEARSON
Engineering Electromagnetics
Engineering Electromagnetics
Electrical Engineering
ISBN:
9780078028151
Author:
Hayt, William H. (william Hart), Jr, BUCK, John A.
Publisher:
Mcgraw-hill Education,