We are designing an air conditioning process that will supply air at 20 [C] and 45% RH to a large production facility. The building is 100 [m] long, 30 [m] wide, and 10 [m] high. Due to off-gassing from some of the processes it is necessary to "turn over" the air every two hour to prevent accumulation of toxic vapors. In other words, the entire volume of air must be replaced by the fresh air flow every two hours. The air conditioning system is designed to handle the most likely extreme temperature which is 40 [C]. The region is known for moderately high humidity, so we will consider and inlet relative humidity of 70%. Answer the following questions to characterize the required air conditioning system. (Hint: the inlet to the facility is the outlet of the AC unit) A. What is the volumetric flow rate required into the facility? B. What is the mass flow rate of dry air into the facility? C. What is the minimum temperature required to meet the relative humidity target for the flow into the facility?
We are designing an air conditioning process that will supply air at 20 [C] and 45% RH to a large production facility. The building is 100 [m] long, 30 [m] wide, and 10 [m] high. Due to off-gassing from some of the processes it is necessary to "turn over" the air every two hour to prevent accumulation of toxic vapors. In other words, the entire volume of air must be replaced by the fresh air flow every two hours. The air conditioning system is designed to handle the most likely extreme temperature which is 40 [C]. The region is known for moderately high humidity, so we will consider and inlet relative humidity of 70%. Answer the following questions to characterize the required air conditioning system. (Hint: the inlet to the facility is the outlet of the AC unit) A. What is the volumetric flow rate required into the facility? B. What is the mass flow rate of dry air into the facility? C. What is the minimum temperature required to meet the relative humidity target for the flow into the facility?
Elements Of Electromagnetics
7th Edition
ISBN:9780190698614
Author:Sadiku, Matthew N. O.
Publisher:Sadiku, Matthew N. O.
ChapterMA: Math Assessment
Section: Chapter Questions
Problem 1.1MA
Related questions
Question
Please show all steps such as enthalpy calculation
![We are designing an air conditioning process that will supply air at 20 [C] and 45% RH to a
large production facility. The building is 100 [m] long, 30 [m] wide, and 10 [m] high. Due to
off-gassing from some of the processes it is necessary to "turn over" the air every two hours
to prevent accumulation of toxic vapors. In other words, the entire volume of air must be
replaced by the fresh air flow every two hours. The air conditioning system is designed to
handle the most likely extreme temperature which is 40 [C]. The region is known for
moderately high humidity, so we will consider and inlet relative humidity of 70%. Answer
the following questions to characterize the required air conditioning system.
(Hint: the inlet to the facility is the outlet of the AC unit)
A. What is the volumetric flow rate required into the facility?
B. What is the mass flow rate of dry air into the facility?
C. What is the minimum temperature required to meet the relative humidity target for the
flow into the facility?](/v2/_next/image?url=https%3A%2F%2Fcontent.bartleby.com%2Fqna-images%2Fquestion%2F45965e93-b769-4ee1-a319-c96c7cb5e0dc%2F4cc39a04-ef46-4863-82d2-990ce24503df%2Fiukmd9_processed.png&w=3840&q=75)
Transcribed Image Text:We are designing an air conditioning process that will supply air at 20 [C] and 45% RH to a
large production facility. The building is 100 [m] long, 30 [m] wide, and 10 [m] high. Due to
off-gassing from some of the processes it is necessary to "turn over" the air every two hours
to prevent accumulation of toxic vapors. In other words, the entire volume of air must be
replaced by the fresh air flow every two hours. The air conditioning system is designed to
handle the most likely extreme temperature which is 40 [C]. The region is known for
moderately high humidity, so we will consider and inlet relative humidity of 70%. Answer
the following questions to characterize the required air conditioning system.
(Hint: the inlet to the facility is the outlet of the AC unit)
A. What is the volumetric flow rate required into the facility?
B. What is the mass flow rate of dry air into the facility?
C. What is the minimum temperature required to meet the relative humidity target for the
flow into the facility?
Expert Solution

Step 1
(b) The relationship between mass and volumetric flow rate , pressure and temperature
for a gas can be determined from the ideal gas law (Eqns 9.4 - 9.6)
(9.4) where
Trending now
This is a popular solution!
Step by step
Solved in 2 steps

Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, mechanical-engineering and related others by exploring similar questions and additional content below.Recommended textbooks for you

Elements Of Electromagnetics
Mechanical Engineering
ISBN:
9780190698614
Author:
Sadiku, Matthew N. O.
Publisher:
Oxford University Press

Mechanics of Materials (10th Edition)
Mechanical Engineering
ISBN:
9780134319650
Author:
Russell C. Hibbeler
Publisher:
PEARSON

Thermodynamics: An Engineering Approach
Mechanical Engineering
ISBN:
9781259822674
Author:
Yunus A. Cengel Dr., Michael A. Boles
Publisher:
McGraw-Hill Education

Elements Of Electromagnetics
Mechanical Engineering
ISBN:
9780190698614
Author:
Sadiku, Matthew N. O.
Publisher:
Oxford University Press

Mechanics of Materials (10th Edition)
Mechanical Engineering
ISBN:
9780134319650
Author:
Russell C. Hibbeler
Publisher:
PEARSON

Thermodynamics: An Engineering Approach
Mechanical Engineering
ISBN:
9781259822674
Author:
Yunus A. Cengel Dr., Michael A. Boles
Publisher:
McGraw-Hill Education

Control Systems Engineering
Mechanical Engineering
ISBN:
9781118170519
Author:
Norman S. Nise
Publisher:
WILEY

Mechanics of Materials (MindTap Course List)
Mechanical Engineering
ISBN:
9781337093347
Author:
Barry J. Goodno, James M. Gere
Publisher:
Cengage Learning

Engineering Mechanics: Statics
Mechanical Engineering
ISBN:
9781118807330
Author:
James L. Meriam, L. G. Kraige, J. N. Bolton
Publisher:
WILEY