Two wattmeters are properly connected to measure the total power drawn by a balanced 3-phase load. If the readings of the wattmeters are 3 kW and 1 kW, the latter being obtained after reversing the connections of its current coil. Find the pf of the load.

Introductory Circuit Analysis (13th Edition)
13th Edition
ISBN:9780133923605
Author:Robert L. Boylestad
Publisher:Robert L. Boylestad
Chapter1: Introduction
Section: Chapter Questions
Problem 1P: Visit your local library (at school or home) and describe the extent to which it provides literature...
icon
Related questions
Question
Answer the following problems in a short/long bond paper size. Round off your answer up to 2
decimals, if applicable. Show your complete solution and box your final answer.
You may not copy the problem.
1. Two wattmeters are properly connected to measure the total power drawn by a balanced
3-phase load. If the readings of the wattmeters are 3 kW and 1 kW, the latter being
obtained after reversing the connections of its current coil. Find the pf of the load.
2. A7.5 hp, 230 V, 3-phase induction motor takes a line current of 18 A, when operating at
rated output at an efficiency of 90%. Find the reading of a wattmeter when this is
inserted to measure the 3-phase power drawn by the T-method.
3. A balanced delta-connected load is connected across a balanced 3-phase, 120 V, 60
Hz, 3-wire system. Two wattmeters are properly connected to measure the power drawn
by the load. If the wattmeters read 1500 W and 500 W, find the complex impedance of
the load per phase.
4. A balanced, 3-phase, 132 kV line supplies power to a balanced load that draws 70.7
MVA at 0.707 pf lagging. A delta-connected capacitor bank is connected in parallel to
correct the pf to unity. Find the reactance per phase of the capacitor bank.
5. It is required to raise the power factor of a 750 kW balanced 3-phase load from 0.70
lagging to 0.90 lagging. The line voltage is 6.9 kV, 60 Hz. Find the capacitance per
phase required for wye-connected capacitor bank.
Transcribed Image Text:Answer the following problems in a short/long bond paper size. Round off your answer up to 2 decimals, if applicable. Show your complete solution and box your final answer. You may not copy the problem. 1. Two wattmeters are properly connected to measure the total power drawn by a balanced 3-phase load. If the readings of the wattmeters are 3 kW and 1 kW, the latter being obtained after reversing the connections of its current coil. Find the pf of the load. 2. A7.5 hp, 230 V, 3-phase induction motor takes a line current of 18 A, when operating at rated output at an efficiency of 90%. Find the reading of a wattmeter when this is inserted to measure the 3-phase power drawn by the T-method. 3. A balanced delta-connected load is connected across a balanced 3-phase, 120 V, 60 Hz, 3-wire system. Two wattmeters are properly connected to measure the power drawn by the load. If the wattmeters read 1500 W and 500 W, find the complex impedance of the load per phase. 4. A balanced, 3-phase, 132 kV line supplies power to a balanced load that draws 70.7 MVA at 0.707 pf lagging. A delta-connected capacitor bank is connected in parallel to correct the pf to unity. Find the reactance per phase of the capacitor bank. 5. It is required to raise the power factor of a 750 kW balanced 3-phase load from 0.70 lagging to 0.90 lagging. The line voltage is 6.9 kV, 60 Hz. Find the capacitance per phase required for wye-connected capacitor bank.
Expert Solution
trending now

Trending now

This is a popular solution!

steps

Step by step

Solved in 2 steps with 2 images

Blurred answer
Knowledge Booster
Source transformation method
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.
Similar questions
Recommended textbooks for you
Introductory Circuit Analysis (13th Edition)
Introductory Circuit Analysis (13th Edition)
Electrical Engineering
ISBN:
9780133923605
Author:
Robert L. Boylestad
Publisher:
PEARSON
Delmar's Standard Textbook Of Electricity
Delmar's Standard Textbook Of Electricity
Electrical Engineering
ISBN:
9781337900348
Author:
Stephen L. Herman
Publisher:
Cengage Learning
Programmable Logic Controllers
Programmable Logic Controllers
Electrical Engineering
ISBN:
9780073373843
Author:
Frank D. Petruzella
Publisher:
McGraw-Hill Education
Fundamentals of Electric Circuits
Fundamentals of Electric Circuits
Electrical Engineering
ISBN:
9780078028229
Author:
Charles K Alexander, Matthew Sadiku
Publisher:
McGraw-Hill Education
Electric Circuits. (11th Edition)
Electric Circuits. (11th Edition)
Electrical Engineering
ISBN:
9780134746968
Author:
James W. Nilsson, Susan Riedel
Publisher:
PEARSON
Engineering Electromagnetics
Engineering Electromagnetics
Electrical Engineering
ISBN:
9780078028151
Author:
Hayt, William H. (william Hart), Jr, BUCK, John A.
Publisher:
Mcgraw-hill Education,