TWO SYSTEMS OF TARIFF ARE AVAILABLE FOR A FACTORY WORKING 8 HOURS A DAY FOR97 WORKING DAYS IN A YEAR. wwwwwwwww (1) High-VOLTAGE SUpply at 5 paise per UNIT PLUS Rs 4.50 PER MONTH PER KVA OF MAXIMUM DEMAND. (2) Low vOLTAGE SUPPLY AT Rs 5 PER MONTH PER KVA of MAXIMUM DEMAND PLUS 5-5 paise per unit. The facTORY HAS AN AVERAGE LOAD of 200 KW AT 0.8 P.F. AND A MAXIMUM DEMAND OF 250 kW AT THE SAME P.F. THE HIGH VOLTAGE EQUIPMENT COSTS RS 50 PER KVA AND THE LOSSES CAN BE TAKEN AS 4%. INTEREST AND DEPRECIATION CHARGES ARE 12%. CALCULATE THE DIFFERENCE IN THE ANNUAL COSTS BETWEEN THE TWO SYSTEMS. I

Introductory Circuit Analysis (13th Edition)
13th Edition
ISBN:9780133923605
Author:Robert L. Boylestad
Publisher:Robert L. Boylestad
Chapter1: Introduction
Section: Chapter Questions
Problem 1P: Visit your local library (at school or home) and describe the extent to which it provides literature...
icon
Related questions
Question

Electrical please help!

TWO SYSTEMS OF TARIFF ARE AVAILABLE
FOR A FACTORY WORKING 8 HOURS A DAY
FOR97 WORKING DAYS IN A YEAR.
wwwwwwww
(1) High-voLTAGE SUPply at 5 pAISE PER
UNIT PLUS Rs 4.50 PER MONTH PER KVA
OF MAXIMUM DEMAND.
(2) Low VOLTAGE SUPPLY AT Rs 5 PER
MONTH PER KVA OF MAXIMUM DEMAND
PLUS 5-5 paise per unit. The facTORY
HAS AN AVERAGE LOAD of 200 KW AT 0.8
P.F. AND A MAXIMUM DEMAND OF 250 kW
www
AT THE SAME P.F. THE HIGH VOLTAGE
EQUIPMENT COSTS RS 50 PER KVA AND
THE LOSSES CAN BE TAKEN AS 4%.
INTEREST AND DEPRECIATION CHARGES ARE
12%. CALCULATE THE DIFFERENCE IN THE
ANNUAL COSTS BETWEEN THE TWO
SYSTEMS.
I
Transcribed Image Text:TWO SYSTEMS OF TARIFF ARE AVAILABLE FOR A FACTORY WORKING 8 HOURS A DAY FOR97 WORKING DAYS IN A YEAR. wwwwwwww (1) High-voLTAGE SUPply at 5 pAISE PER UNIT PLUS Rs 4.50 PER MONTH PER KVA OF MAXIMUM DEMAND. (2) Low VOLTAGE SUPPLY AT Rs 5 PER MONTH PER KVA OF MAXIMUM DEMAND PLUS 5-5 paise per unit. The facTORY HAS AN AVERAGE LOAD of 200 KW AT 0.8 P.F. AND A MAXIMUM DEMAND OF 250 kW www AT THE SAME P.F. THE HIGH VOLTAGE EQUIPMENT COSTS RS 50 PER KVA AND THE LOSSES CAN BE TAKEN AS 4%. INTEREST AND DEPRECIATION CHARGES ARE 12%. CALCULATE THE DIFFERENCE IN THE ANNUAL COSTS BETWEEN THE TWO SYSTEMS. I
Expert Solution
trending now

Trending now

This is a popular solution!

steps

Step by step

Solved in 2 steps with 2 images

Blurred answer
Knowledge Booster
Lag, Lead and Lead-Lag Compensator
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.
Recommended textbooks for you
Introductory Circuit Analysis (13th Edition)
Introductory Circuit Analysis (13th Edition)
Electrical Engineering
ISBN:
9780133923605
Author:
Robert L. Boylestad
Publisher:
PEARSON
Delmar's Standard Textbook Of Electricity
Delmar's Standard Textbook Of Electricity
Electrical Engineering
ISBN:
9781337900348
Author:
Stephen L. Herman
Publisher:
Cengage Learning
Programmable Logic Controllers
Programmable Logic Controllers
Electrical Engineering
ISBN:
9780073373843
Author:
Frank D. Petruzella
Publisher:
McGraw-Hill Education
Fundamentals of Electric Circuits
Fundamentals of Electric Circuits
Electrical Engineering
ISBN:
9780078028229
Author:
Charles K Alexander, Matthew Sadiku
Publisher:
McGraw-Hill Education
Electric Circuits. (11th Edition)
Electric Circuits. (11th Edition)
Electrical Engineering
ISBN:
9780134746968
Author:
James W. Nilsson, Susan Riedel
Publisher:
PEARSON
Engineering Electromagnetics
Engineering Electromagnetics
Electrical Engineering
ISBN:
9780078028151
Author:
Hayt, William H. (william Hart), Jr, BUCK, John A.
Publisher:
Mcgraw-hill Education,