Two synchronous generators supply a load of 5 MVA with a power factor of 0.8. No-load frequency of the first generator is fni,1=52 Hz. Spi is 2 MW/Hz and Sp2 is 1 MW/Hz. The system is operating at 50.5 Hz frequency. a. Find the no-load frequency of 2nd generator. Find the power sharing between 2 generators. Sketch the (P-f) graph. b. When loading level increases %10 Find the new system frequency and power sharing Sketch the (P-f) graph. c. To restore the frequency value of the first condition (a), the governor changes the no-load frequency of 1st generator. Find the new fnl,1 and the new power sharing between 2 generators. Sketch the (P-f) graph.

Introductory Circuit Analysis (13th Edition)
13th Edition
ISBN:9780133923605
Author:Robert L. Boylestad
Publisher:Robert L. Boylestad
Chapter1: Introduction
Section: Chapter Questions
Problem 1P: Visit your local library (at school or home) and describe the extent to which it provides literature...
icon
Related questions
icon
Concept explainers
Question

I need to answer of this quesiton also there is writing %10 in red text on b part. Thank you for support

Two synchronous generators supply a load of 5 MVA with a power factor of 0.8. No-load frequency of the first
generator is fni,1=52 Hz. Spi is 2 MW/Hz and Sp2 is 1 MW/Hz. The system is operating at 50.5 Hz frequency.
a. Find the no-load frequency of 2nd generator. Find the power sharing between 2 generators. Sketch the (P-f) graph.
b. When loading level increases
%10
Find the new system frequency and power sharing Sketch the (P-f) graph.
c. To restore the frequency value of the first condition (a), the governor changes the no-load frequency of 1st generator.
Find the new fnl,1 and the new power sharing between 2 generators. Sketch the (P-f) graph.
Transcribed Image Text:Two synchronous generators supply a load of 5 MVA with a power factor of 0.8. No-load frequency of the first generator is fni,1=52 Hz. Spi is 2 MW/Hz and Sp2 is 1 MW/Hz. The system is operating at 50.5 Hz frequency. a. Find the no-load frequency of 2nd generator. Find the power sharing between 2 generators. Sketch the (P-f) graph. b. When loading level increases %10 Find the new system frequency and power sharing Sketch the (P-f) graph. c. To restore the frequency value of the first condition (a), the governor changes the no-load frequency of 1st generator. Find the new fnl,1 and the new power sharing between 2 generators. Sketch the (P-f) graph.
Expert Solution
steps

Step by step

Solved in 10 steps with 13 images

Blurred answer
Knowledge Booster
Measuring instrument
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.
Recommended textbooks for you
Introductory Circuit Analysis (13th Edition)
Introductory Circuit Analysis (13th Edition)
Electrical Engineering
ISBN:
9780133923605
Author:
Robert L. Boylestad
Publisher:
PEARSON
Delmar's Standard Textbook Of Electricity
Delmar's Standard Textbook Of Electricity
Electrical Engineering
ISBN:
9781337900348
Author:
Stephen L. Herman
Publisher:
Cengage Learning
Programmable Logic Controllers
Programmable Logic Controllers
Electrical Engineering
ISBN:
9780073373843
Author:
Frank D. Petruzella
Publisher:
McGraw-Hill Education
Fundamentals of Electric Circuits
Fundamentals of Electric Circuits
Electrical Engineering
ISBN:
9780078028229
Author:
Charles K Alexander, Matthew Sadiku
Publisher:
McGraw-Hill Education
Electric Circuits. (11th Edition)
Electric Circuits. (11th Edition)
Electrical Engineering
ISBN:
9780134746968
Author:
James W. Nilsson, Susan Riedel
Publisher:
PEARSON
Engineering Electromagnetics
Engineering Electromagnetics
Electrical Engineering
ISBN:
9780078028151
Author:
Hayt, William H. (william Hart), Jr, BUCK, John A.
Publisher:
Mcgraw-hill Education,