Three shunt generators operating in parallel supply a total load current of 2000 amperes. Each machine has a field resistance of 40 ohms and an armature resistance of 0.02 ohm. The emfs generated are 240, 242 and 245 volts respectively. Determine current delivered by each generator.
Synchronous Generator
In comparison to an asynchronous generator, it is a machine where the rotor speed is equal to the rotating magnetic field produced by the stator, i.e., mechanical speed is equal to the electrical speed, thus called synchronous, and not asynchronous.
Salient Pole Rotor
Salient pole rotor includes a large number of exposed poles mounted on a magnetic wheel. The construction of a bright pole is as shown in the image on the left. The proposed poles are made of metal laminations. The rotor winding is provided on these poles and is supported by pole shoes.
10. Three shunt generators operating in parallel supply a total load current of 2000 amperes. Each machine has
a field resistance of 40 ohms and an armature resistance of 0.02 ohm. The emfs generated are 240, 242 and
245 volts respectively. Determine current delivered by each generator.
Step by step
Solved in 3 steps with 3 images