*There are two input ports F1H and F2H and one output port FOH. *All the switches of F1H&F2H are connected to the data line Do to D7 of 8085 microprocessor. *All DO to D7 lines of 8085 are connected to 00 to 07 of output port. Write program for the following instructions: 1. Only when both the SO switch of F1H & F2H are ON, the 04 to 07 belts should be ON irrespective of the conditions of both S4 to S7 switch positions. 2. If the both the SO switches are on, the P-ON light should be enabled followed the conveyer belt operation. 3. When the conveyer belts are started to process, the M-ON light should the indicated. 4. If there is any emergency condition, E-On alarm should be enabled followed by the switching off the conveyer belts. 5. If the conveyer belts are stopped, the P-OFF indicator should be enabled. Since we don't have the output port operation in the simulator, you can use the following to indicate the output process on. Output devices ON condition OFF condition 00 Store 01H in 2000H Store OFH in 2000H 01 Store 01H in 2001H Store OFH in 2001H 02 Store 01H in 2002H Store OFH in 2002H 03 Store 01H in 2003H Store OFH in 2003H 04 Store 01H in 2004H Store OFH in 2004H 05 Store 01H in 2005H Store OFH in 2005H 06 Store 01H in 2006H Store OFH in 2006H 07 Store 01H in 2007H Store OFH in 2007H

Computer Networking: A Top-Down Approach (7th Edition)
7th Edition
ISBN:9780133594140
Author:James Kurose, Keith Ross
Publisher:James Kurose, Keith Ross
Chapter1: Computer Networks And The Internet
Section: Chapter Questions
Problem R1RQ: What is the difference between a host and an end system? List several different types of end...
icon
Related questions
Question
100%

In 8085

Programming should be in sim8085.Com

DO
DO
so
S1
S2
INPUT PORT 1
MICROPROCESSOR
S3
S4
F1 H
8085
S5
S6
S7
D7
D7
DO
DO
so
P-ON
00
S1
01
M-ON
S2
E-ON
02
OUPUT PORT
03
INPUT PORT 2
S3
P-OFF
S4
F2 H
FO H
04
B1
S5
05
B2
S6
06
ВЗ
S7
07
В4
D7
D7
*There are two input ports F1H and F2H and one output port FOH.
*All the switches of F1H&F2H are connected to the data line Do to D7 of 8085 microprocessor.
*All DO to D7 lines of 8085 are connected to 00 to 07 of output port.
Write program for the following instructions:
1. Only when both the S0 switch of F1H & F2H are ON, the 04 to 07 belts should be ON
irrespective of the conditions of both S4 to S7 switch positions.
2. If the both the SO switches are on, the P-ON light should be enabled followed the conveyer
belt operation.
3. When the conveyer belts are started to process, the M-ON light should the indicated.
4. If there is any emergency condition, E-On alarm should be enabled followed by the switching
off the conveyer belts.
5. If the conveyer belts are stopped, the P-OFF indicator should be enabled.
Since we don't have the output port operation in the simulator, you can use the following to
indicate the output process on.
Output devices
ON condition
OFF condition
00
Store 01H in 2000H
Store OFH in 2000H
01
Store 01H in 2001H
Store OFH in 2001H
02
Store 01H in 2002H
Store OFH in 2002H
03
Store 01H in 2003H
Store OFH in 2003H
04
Store 01H in 2004H
Store OFH in 2004H
05
Store 01H in 2005H
Store OFH in 2005H
06
Store 01H in 2006H
Store OFH in 2006H
07
Store 01H in 2007H
Store OFH in 2007H
Transcribed Image Text:DO DO so S1 S2 INPUT PORT 1 MICROPROCESSOR S3 S4 F1 H 8085 S5 S6 S7 D7 D7 DO DO so P-ON 00 S1 01 M-ON S2 E-ON 02 OUPUT PORT 03 INPUT PORT 2 S3 P-OFF S4 F2 H FO H 04 B1 S5 05 B2 S6 06 ВЗ S7 07 В4 D7 D7 *There are two input ports F1H and F2H and one output port FOH. *All the switches of F1H&F2H are connected to the data line Do to D7 of 8085 microprocessor. *All DO to D7 lines of 8085 are connected to 00 to 07 of output port. Write program for the following instructions: 1. Only when both the S0 switch of F1H & F2H are ON, the 04 to 07 belts should be ON irrespective of the conditions of both S4 to S7 switch positions. 2. If the both the SO switches are on, the P-ON light should be enabled followed the conveyer belt operation. 3. When the conveyer belts are started to process, the M-ON light should the indicated. 4. If there is any emergency condition, E-On alarm should be enabled followed by the switching off the conveyer belts. 5. If the conveyer belts are stopped, the P-OFF indicator should be enabled. Since we don't have the output port operation in the simulator, you can use the following to indicate the output process on. Output devices ON condition OFF condition 00 Store 01H in 2000H Store OFH in 2000H 01 Store 01H in 2001H Store OFH in 2001H 02 Store 01H in 2002H Store OFH in 2002H 03 Store 01H in 2003H Store OFH in 2003H 04 Store 01H in 2004H Store OFH in 2004H 05 Store 01H in 2005H Store OFH in 2005H 06 Store 01H in 2006H Store OFH in 2006H 07 Store 01H in 2007H Store OFH in 2007H
Expert Solution
steps

Step by step

Solved in 4 steps with 2 images

Blurred answer
Recommended textbooks for you
Computer Networking: A Top-Down Approach (7th Edi…
Computer Networking: A Top-Down Approach (7th Edi…
Computer Engineering
ISBN:
9780133594140
Author:
James Kurose, Keith Ross
Publisher:
PEARSON
Computer Organization and Design MIPS Edition, Fi…
Computer Organization and Design MIPS Edition, Fi…
Computer Engineering
ISBN:
9780124077263
Author:
David A. Patterson, John L. Hennessy
Publisher:
Elsevier Science
Network+ Guide to Networks (MindTap Course List)
Network+ Guide to Networks (MindTap Course List)
Computer Engineering
ISBN:
9781337569330
Author:
Jill West, Tamara Dean, Jean Andrews
Publisher:
Cengage Learning
Concepts of Database Management
Concepts of Database Management
Computer Engineering
ISBN:
9781337093422
Author:
Joy L. Starks, Philip J. Pratt, Mary Z. Last
Publisher:
Cengage Learning
Prelude to Programming
Prelude to Programming
Computer Engineering
ISBN:
9780133750423
Author:
VENIT, Stewart
Publisher:
Pearson Education
Sc Business Data Communications and Networking, T…
Sc Business Data Communications and Networking, T…
Computer Engineering
ISBN:
9781119368830
Author:
FITZGERALD
Publisher:
WILEY