The sketch graph shows the corrected count rate measured for the decay of a radioactive sample (the sample-detector distance is constant): corrected count rate/s¹

icon
Related questions
Question
100%

Asap plz 

-
The sketch graph shows the corrected count rate measured for the decay of
a radioactive sample (the sample-detector distance is constant):
corrected count rate/s-¹
1200
500
0
10
t/s
(a) At time t=0s, what factors will affect the count-rate measured?
(b) If the count-rate is 1200s-¹ at t=0s, and is 500s¹ after 10s, find the
decay constant for the radioactive isotope.
(c) What is the half-life of this isotope? `
Transcribed Image Text:- The sketch graph shows the corrected count rate measured for the decay of a radioactive sample (the sample-detector distance is constant): corrected count rate/s-¹ 1200 500 0 10 t/s (a) At time t=0s, what factors will affect the count-rate measured? (b) If the count-rate is 1200s-¹ at t=0s, and is 500s¹ after 10s, find the decay constant for the radioactive isotope. (c) What is the half-life of this isotope? `