The parameters of a three-phase transmission line are given as Z = (12.84 + j72, 76)Ω and y = j5, 83x10^-4 mho. At the end of the line, a power of 55 MVA with a power factor of 0.8 is drawn under 132 kV voltage. Accordingly, calculate the line head voltage, active and reactive power values per line, and voltage regulation of the line using the nominal π circuit.
Short Transmission Line
A short transmission line is a transmission line that has a length less than 80 kilometers, an operating voltage level of less than 20 kV, and zero capacitance effect.
Power Flow Analysis
Power flow analysis is a topic in power engineering. It is the flow of electric power in a system. The power flow analysis is preliminary used for the various components of Alternating Current (AC) power, such as the voltage, current, real power, reactive power, and voltage angles under given load conditions and is often known as a load flow study or load flow analysis.
Complex Form
A power system is defined as the connection or network of the various components that convert the non-electrical energy into the electric form and supply the electric form of energy from the source to the load. The power system is an important parameter in power engineering and the electrical engineering profession. The powers in the power system are primarily categorized into two types- active power and reactive power.
Question-2) The parameters of a three-phase transmission line are given as Z = (12.84 + j72, 76)Ω and y = j5, 83x10^-4 mho. At the end of the line, a power of 55 MVA with a power factor of 0.8 is drawn under 132 kV voltage. Accordingly, calculate the line head voltage, active and reactive power values per line, and voltage regulation of the line using the nominal π circuit.
7-) Since 55 MVA power is drawn from the end of the line under the conditions mentioned above, calculate the line head voltage (phase-phase voltage) and enter it in the box below. (The value will be entered in kiloVolts. Only the amplitude value of the voltage will be entered. The phase value will NOT be entered!!! Two digits after the comma will be sufficient. )
8-) Since 55 MVA power is drawn from the end of the line under the conditions mentioned above, calculate the active power value per line and enter it in the box below. (The value will be entered in MegaWatt. It will be sufficient to take two digits after the comma.)
9-) Since 55 MVA power is drawn from the end of the line under the conditions mentioned above, calculate the reactive power value per line and enter it in the box below. (The value will be entered in MegaVoltAmperReactive (MVAR). Two digits after the comma will be sufficient.)
10-) Since 55 MVA power is drawn from the end of the line under the conditions mentioned above, calculate the voltage regulation value of the line and enter it in the box below. ( If the value is found to be 35.72%, it will only be entered as 35.72. It will be sufficient to take two digits after the comma.)
NOTE: If the information in the text and the photo is different, please solve the question using the information given in the photo.
Help me please... Thank you so much.
Step by step
Solved in 4 steps with 4 images