The output of a compressor plant delivering 600 m3 of free air/hr at 7 bar gauge at 20 oC passes through arefrigeration type dehumidifier where it is cooled to 1 oC. How much water should be collected from thedehumidifier per hour ? Please choice one below: a. 5.124 kg/hr b. 0.909 kg/hr c. 0.408 kg/hr d. 3.275 kg/hr e. 1.317 kg/hr
Heat Exchangers
Heat exchangers are the types of equipment that are primarily employed to transfer the thermal energy from one fluid to another, provided that one of the fluids should be at a higher thermal energy content than the other fluid.
Heat Exchanger
The heat exchanger is a combination of two words ''Heat'' and ''Exchanger''. It is a mechanical device that is used to exchange heat energy between two fluids.
The output of a compressor plant delivering 600 m3 of free air/hr at 7 bar gauge at 20 oC passes through arefrigeration type dehumidifier where it is cooled to 1 oC. How much water should be collected from thedehumidifier per hour ?
Please choice one below:
a. 5.124 kg/hr
b. 0.909 kg/hr
c. 0.408 kg/hr
d. 3.275 kg/hr
e. 1.317 kg/hr
Step by step
Solved in 3 steps with 4 images