The one-line diagram of an unloaded power system is shown below. T | 1000 T Reactances of the two sections of transmission line are shown in the diagram. The generators and transformers are rated as follows: Generator 1: 20 MVA 13.8 KV, X = 0.2 per unit Generator 2: 30 MVA, 18 KV, X= 0.2 per unit Generator 3: 30 MVA, 20 KV, X = 0.2 per unit Transformer T1: 25 MVA, 220Y/13.8A KV, X= 10% Transformer T: Single-phase units each rated 10 MVA, 127/18 KV, X = 10% Transformer T: 35 MVA, 220Y/22Y kV, X = 10% Compute for the reactances per unit and by choosing a base of 50 MVA 13.8KV in the circuit of generator 1. Show your complete solutions (41-48): 41. What is the generator 1 per unit reactance? a. 0.3333 b. 0.2755 c. 0.5 d. 0.2 42. What is the transformer 1 per unit reactance? a. 0.2 b. 0.1667 c. 0.1429 d. 0.0826 43. What is the transmission line 1 (point B to C) per unit reactance? a. 0.1033 b. 0.0826 C. 0.5 d. 0.2 44. What is the transformer 3 per unit reactance? a. 0.2 b. 0.1667 c. 0.1429 d. 0.0826 45. What is the transmission line 2 (point C to E) per unit reactance? a. 0.1033 c. 0.5 b. 0.0826 d. 0.2 46. What is the per unit reactance of the generator 3? a. 0.3333 b. 0.2755 c. 0.5 d. 0.2 47. What is the transformer 2 per unit reactance? a. 0.2 b. 0.1667 c. 0.1429 d. 0.0826 48 What is the generator 2 per unit reactance? a. 0.3333 b.0.2755 c. 0.5 d. 0.2

Introductory Circuit Analysis (13th Edition)
13th Edition
ISBN:9780133923605
Author:Robert L. Boylestad
Publisher:Robert L. Boylestad
Chapter1: Introduction
Section: Chapter Questions
Problem 1P: Visit your local library (at school or home) and describe the extent to which it provides literature...
icon
Related questions
Question
The one-line diagram of an unloaded power system is shown below.
T2
j 80 0
j 100 2
E
Y uw Ts
Reactances of the two sections of transmission line are shown in the
diagram. The generators and transformers are rated as follows:
Generator 1: 20 MVA, 13.8 kV, X" = 0.2 per unit
Generator 2: 30 MVA, 18 kV, X = 0.2 per unit
Generator 3: 30 MVA, 20 kV, X" = 0.2 per unit
Transformer T1: 25 MVA, 220Y/13.8A kV, X = 10%
Transformer T2: Single-phase units each rated 10 MVA, 127/18 kV, X = 10%
Transformer T3: 35 MVA, 220Y/22Y kV, X = 10%
Compute for the reactances per unit and by choosing a base of 50 MVA,
13.8kV in the circuit of generator 1.
Show your complete solutions (41-48):
41. What is the generator 1 per unit reactance?
a. 0.3333
b. 0.2755
c. 0.5
d. 0.2
42. What is the transformer 1 per unit reactance?
a. 0.2
b. 0.1667
c. 0.1429
d. 0.0826
43. What is the transmission line 1 (point B to C) per unit reactance?
a. 0.1033
b. 0.0826
c. 0.5
d. 0.2
44. What is the transformer 3 per unit reactance?
a. 0.2
b. 0.1667
c. 0.1429
d. 0.0826
45. What is the transmission line 2 (point C to E) per unit reactance?
a. 0.1033
b. 0.0826
c. 0.5
d. 0.2
46. What is the per unit reactance of the generator 3?
a. 0.3333
b. 0.2755
c. 0.5
d. 0.2
47. What is the transformer 2 per unit reactance?
а. О.2
b. 0.1667
c. 0.1429
d. 0.0826
48 What is the generator 2 per unit reactance?
a. 0.3333
b. 0.2755
c. 0.5
d. 0.2
Transcribed Image Text:The one-line diagram of an unloaded power system is shown below. T2 j 80 0 j 100 2 E Y uw Ts Reactances of the two sections of transmission line are shown in the diagram. The generators and transformers are rated as follows: Generator 1: 20 MVA, 13.8 kV, X" = 0.2 per unit Generator 2: 30 MVA, 18 kV, X = 0.2 per unit Generator 3: 30 MVA, 20 kV, X" = 0.2 per unit Transformer T1: 25 MVA, 220Y/13.8A kV, X = 10% Transformer T2: Single-phase units each rated 10 MVA, 127/18 kV, X = 10% Transformer T3: 35 MVA, 220Y/22Y kV, X = 10% Compute for the reactances per unit and by choosing a base of 50 MVA, 13.8kV in the circuit of generator 1. Show your complete solutions (41-48): 41. What is the generator 1 per unit reactance? a. 0.3333 b. 0.2755 c. 0.5 d. 0.2 42. What is the transformer 1 per unit reactance? a. 0.2 b. 0.1667 c. 0.1429 d. 0.0826 43. What is the transmission line 1 (point B to C) per unit reactance? a. 0.1033 b. 0.0826 c. 0.5 d. 0.2 44. What is the transformer 3 per unit reactance? a. 0.2 b. 0.1667 c. 0.1429 d. 0.0826 45. What is the transmission line 2 (point C to E) per unit reactance? a. 0.1033 b. 0.0826 c. 0.5 d. 0.2 46. What is the per unit reactance of the generator 3? a. 0.3333 b. 0.2755 c. 0.5 d. 0.2 47. What is the transformer 2 per unit reactance? а. О.2 b. 0.1667 c. 0.1429 d. 0.0826 48 What is the generator 2 per unit reactance? a. 0.3333 b. 0.2755 c. 0.5 d. 0.2
Expert Solution
trending now

Trending now

This is a popular solution!

steps

Step by step

Solved in 4 steps with 4 images

Blurred answer
Knowledge Booster
Maximum power transfer theorem
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Introductory Circuit Analysis (13th Edition)
Introductory Circuit Analysis (13th Edition)
Electrical Engineering
ISBN:
9780133923605
Author:
Robert L. Boylestad
Publisher:
PEARSON
Delmar's Standard Textbook Of Electricity
Delmar's Standard Textbook Of Electricity
Electrical Engineering
ISBN:
9781337900348
Author:
Stephen L. Herman
Publisher:
Cengage Learning
Programmable Logic Controllers
Programmable Logic Controllers
Electrical Engineering
ISBN:
9780073373843
Author:
Frank D. Petruzella
Publisher:
McGraw-Hill Education
Fundamentals of Electric Circuits
Fundamentals of Electric Circuits
Electrical Engineering
ISBN:
9780078028229
Author:
Charles K Alexander, Matthew Sadiku
Publisher:
McGraw-Hill Education
Electric Circuits. (11th Edition)
Electric Circuits. (11th Edition)
Electrical Engineering
ISBN:
9780134746968
Author:
James W. Nilsson, Susan Riedel
Publisher:
PEARSON
Engineering Electromagnetics
Engineering Electromagnetics
Electrical Engineering
ISBN:
9780078028151
Author:
Hayt, William H. (william Hart), Jr, BUCK, John A.
Publisher:
Mcgraw-hill Education,