The input impedance of a particular commercial true rms multimeter can be considered to be the parallel combination of a resistance of 10x106 n and a capacitance of 100 pF. The multimeter is being used to measure the output voltage of a transducer with a 50 kHz sinusoidal output voltage. The Thevenin equivalent voltage and impedance of the transducer, relative to its output terminals, are 1 volt (rms) and 23.85 ko respectively. The Thevenin impedance may be assumed to be purely resistive. Which one is the correct statement? Select one: O a. The reading of the voltmeter will be 0.80 V O b. The reading of the voltmeter will be 1.0 V O c. The reading of the voltmeter will be 0.60 V O d. The reading of the voltmeter will be 0.57 V

Introductory Circuit Analysis (13th Edition)
13th Edition
ISBN:9780133923605
Author:Robert L. Boylestad
Publisher:Robert L. Boylestad
Chapter1: Introduction
Section: Chapter Questions
Problem 1P: Visit your local library (at school or home) and describe the extent to which it provides literature...
icon
Related questions
Question

please include working

The input impedance of a particular commercial true rms multimeter can be considered to
be the parallel combination of a resistance of 10x106 n and a capacitance of 100 pF. The
multimeter is being used to measure the output voltage of a transducer with a 50 kHz
sinusoidal output voltage. The Thevenin equivalent voltage and impedance of the
transducer, relative to its output terminals, are 1 volt (rms) and 23.85 kn respectively. The
Thevenin impedance may be assumed to be purely resistive.
Which one is the correct statement?
Select one:
O a. The reading of the voltmeter will be 0.80 V
O b. The reading of the voltmeter will be 1.0 V
O c. The reading of the voltmeter will be 0.60 V
O d. The reading of the voltmeter will be 0.57 V
Transcribed Image Text:The input impedance of a particular commercial true rms multimeter can be considered to be the parallel combination of a resistance of 10x106 n and a capacitance of 100 pF. The multimeter is being used to measure the output voltage of a transducer with a 50 kHz sinusoidal output voltage. The Thevenin equivalent voltage and impedance of the transducer, relative to its output terminals, are 1 volt (rms) and 23.85 kn respectively. The Thevenin impedance may be assumed to be purely resistive. Which one is the correct statement? Select one: O a. The reading of the voltmeter will be 0.80 V O b. The reading of the voltmeter will be 1.0 V O c. The reading of the voltmeter will be 0.60 V O d. The reading of the voltmeter will be 0.57 V
Expert Solution
steps

Step by step

Solved in 2 steps with 1 images

Blurred answer
Knowledge Booster
Economic load dispatch
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.
Recommended textbooks for you
Introductory Circuit Analysis (13th Edition)
Introductory Circuit Analysis (13th Edition)
Electrical Engineering
ISBN:
9780133923605
Author:
Robert L. Boylestad
Publisher:
PEARSON
Delmar's Standard Textbook Of Electricity
Delmar's Standard Textbook Of Electricity
Electrical Engineering
ISBN:
9781337900348
Author:
Stephen L. Herman
Publisher:
Cengage Learning
Programmable Logic Controllers
Programmable Logic Controllers
Electrical Engineering
ISBN:
9780073373843
Author:
Frank D. Petruzella
Publisher:
McGraw-Hill Education
Fundamentals of Electric Circuits
Fundamentals of Electric Circuits
Electrical Engineering
ISBN:
9780078028229
Author:
Charles K Alexander, Matthew Sadiku
Publisher:
McGraw-Hill Education
Electric Circuits. (11th Edition)
Electric Circuits. (11th Edition)
Electrical Engineering
ISBN:
9780134746968
Author:
James W. Nilsson, Susan Riedel
Publisher:
PEARSON
Engineering Electromagnetics
Engineering Electromagnetics
Electrical Engineering
ISBN:
9780078028151
Author:
Hayt, William H. (william Hart), Jr, BUCK, John A.
Publisher:
Mcgraw-hill Education,