The incremental cost (in Rupees/MWh) of operating two generating units are functions of their respective power P₁ and P2 in MW, and are given by dC₁/dP₁ = 0.2P₁ + 50 dC2/dP2 = 0.24P2 + 40 Where 20MW ≤ P1 ≤ 150MW 20MW ≤ P2 ≤ 150MW Foe a certain load demand, P₁ and P2 have been chosen such that dC₁/dP1 = 76 Rs./MWh and dC₁/dP1 = 68.8 Rs./MWh. IF the generations are rescheduled to minimize the total cost, then P2 is
The incremental cost (in Rupees/MWh) of operating two generating units are functions of their respective power P₁ and P2 in MW, and are given by dC₁/dP₁ = 0.2P₁ + 50 dC2/dP2 = 0.24P2 + 40 Where 20MW ≤ P1 ≤ 150MW 20MW ≤ P2 ≤ 150MW Foe a certain load demand, P₁ and P2 have been chosen such that dC₁/dP1 = 76 Rs./MWh and dC₁/dP1 = 68.8 Rs./MWh. IF the generations are rescheduled to minimize the total cost, then P2 is
Power System Analysis and Design (MindTap Course List)
6th Edition
ISBN:9781305632134
Author:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Chapter2: Fundamentals
Section: Chapter Questions
Problem 2.16P: A single-phase, 120V(rms),60Hz source supplies power to a series R-L circuit consisting of R=10 and...
Related questions
Question
![The incremental cost (in Rupees/MWh) of operating two generating units are functions of their
respective power P₁ and P2 in MW, and are given by
dC₁/dP₁ = 0.2P₁ + 50
dC2/dP2 = 0.24P2 + 40
Where
20MW ≤ P₁ ≤ 150MW
20MW ≤ P₂ ≤ 150MW
S
Foe a certain load demand, P₁ and P2 have been chosen such that dC₁/dP₁ = 76 Rs./MWh and
dC₁/dP₁ = 68.8 Rs./MWh. IF the generations are rescheduled to minimize the total cost, then P2 is](/v2/_next/image?url=https%3A%2F%2Fcontent.bartleby.com%2Fqna-images%2Fquestion%2F8ab23277-f3e3-4b42-ad9f-211521eb1f40%2F5ae7b086-b343-4b4e-8bfc-9414785ee974%2Frz54pe_processed.jpeg&w=3840&q=75)
Transcribed Image Text:The incremental cost (in Rupees/MWh) of operating two generating units are functions of their
respective power P₁ and P2 in MW, and are given by
dC₁/dP₁ = 0.2P₁ + 50
dC2/dP2 = 0.24P2 + 40
Where
20MW ≤ P₁ ≤ 150MW
20MW ≤ P₂ ≤ 150MW
S
Foe a certain load demand, P₁ and P2 have been chosen such that dC₁/dP₁ = 76 Rs./MWh and
dC₁/dP₁ = 68.8 Rs./MWh. IF the generations are rescheduled to minimize the total cost, then P2 is
Expert Solution
![](/static/compass_v2/shared-icons/check-mark.png)
This question has been solved!
Explore an expertly crafted, step-by-step solution for a thorough understanding of key concepts.
Step by step
Solved in 3 steps with 3 images
![Blurred answer](/static/compass_v2/solution-images/blurred-answer.jpg)
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.Recommended textbooks for you
![Power System Analysis and Design (MindTap Course …](https://www.bartleby.com/isbn_cover_images/9781305632134/9781305632134_smallCoverImage.gif)
Power System Analysis and Design (MindTap Course …
Electrical Engineering
ISBN:
9781305632134
Author:
J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:
Cengage Learning
![Delmar's Standard Textbook Of Electricity](https://www.bartleby.com/isbn_cover_images/9781337900348/9781337900348_smallCoverImage.jpg)
Delmar's Standard Textbook Of Electricity
Electrical Engineering
ISBN:
9781337900348
Author:
Stephen L. Herman
Publisher:
Cengage Learning
![Power System Analysis and Design (MindTap Course …](https://www.bartleby.com/isbn_cover_images/9781305632134/9781305632134_smallCoverImage.gif)
Power System Analysis and Design (MindTap Course …
Electrical Engineering
ISBN:
9781305632134
Author:
J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:
Cengage Learning
![Delmar's Standard Textbook Of Electricity](https://www.bartleby.com/isbn_cover_images/9781337900348/9781337900348_smallCoverImage.jpg)
Delmar's Standard Textbook Of Electricity
Electrical Engineering
ISBN:
9781337900348
Author:
Stephen L. Herman
Publisher:
Cengage Learning