The following data for a 1250 kVA, 0.8 p.f., 50 Hz, 3300 V, 300 rpm star connected alternator is available : Stator turns per phase = 150 = 60 Field turns per pole Effective area per pole = 0.09 m² Airgap length at pole centre = 5.5 mm Field current for full load short circuit current = 80 A = 20% of airgap ATS per pole for iron portion Assuming sinusoidal flux distribution, estimate the values of short circuit ratio and synchronous reactance.
The following data for a 1250 kVA, 0.8 p.f., 50 Hz, 3300 V, 300 rpm star connected alternator is available : Stator turns per phase = 150 = 60 Field turns per pole Effective area per pole = 0.09 m² Airgap length at pole centre = 5.5 mm Field current for full load short circuit current = 80 A = 20% of airgap ATS per pole for iron portion Assuming sinusoidal flux distribution, estimate the values of short circuit ratio and synchronous reactance.
Introductory Circuit Analysis (13th Edition)
13th Edition
ISBN:9780133923605
Author:Robert L. Boylestad
Publisher:Robert L. Boylestad
Chapter1: Introduction
Section: Chapter Questions
Problem 1P: Visit your local library (at school or home) and describe the extent to which it provides literature...
Related questions
Concept explainers
Synchronous Generator
In comparison to an asynchronous generator, it is a machine where the rotor speed is equal to the rotating magnetic field produced by the stator, i.e., mechanical speed is equal to the electrical speed, thus called synchronous, and not asynchronous.
Salient Pole Rotor
Salient pole rotor includes a large number of exposed poles mounted on a magnetic wheel. The construction of a bright pole is as shown in the image on the left. The proposed poles are made of metal laminations. The rotor winding is provided on these poles and is supported by pole shoes.
Question

Transcribed Image Text:The following data for a 1250 kVA, 0.8 p.f., 50 Hz, 3300 V, 300 rpm star connected alternator is available :
Stator turns per phase
150
Field turns per pole
Effective area per pole
Airgap length at pole centre
Field current for full load short circuit current
ATS per pole for iron portion
Assuming sinusoidal flux distribution, estimate the values of short circuit ratio and synchronous reactance.
=
= 60
= 0.09 m²
= 5.5 mm
= 80 A
= 20% of airgap
Expert Solution

Step 1
Step by step
Solved in 2 steps with 2 images

Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.Recommended textbooks for you

Introductory Circuit Analysis (13th Edition)
Electrical Engineering
ISBN:
9780133923605
Author:
Robert L. Boylestad
Publisher:
PEARSON

Delmar's Standard Textbook Of Electricity
Electrical Engineering
ISBN:
9781337900348
Author:
Stephen L. Herman
Publisher:
Cengage Learning

Programmable Logic Controllers
Electrical Engineering
ISBN:
9780073373843
Author:
Frank D. Petruzella
Publisher:
McGraw-Hill Education

Introductory Circuit Analysis (13th Edition)
Electrical Engineering
ISBN:
9780133923605
Author:
Robert L. Boylestad
Publisher:
PEARSON

Delmar's Standard Textbook Of Electricity
Electrical Engineering
ISBN:
9781337900348
Author:
Stephen L. Herman
Publisher:
Cengage Learning

Programmable Logic Controllers
Electrical Engineering
ISBN:
9780073373843
Author:
Frank D. Petruzella
Publisher:
McGraw-Hill Education

Fundamentals of Electric Circuits
Electrical Engineering
ISBN:
9780078028229
Author:
Charles K Alexander, Matthew Sadiku
Publisher:
McGraw-Hill Education

Electric Circuits. (11th Edition)
Electrical Engineering
ISBN:
9780134746968
Author:
James W. Nilsson, Susan Riedel
Publisher:
PEARSON

Engineering Electromagnetics
Electrical Engineering
ISBN:
9780078028151
Author:
Hayt, William H. (william Hart), Jr, BUCK, John A.
Publisher:
Mcgraw-hill Education,