The field and armature resistance of a four-pole shunt generator with lap-connected armature is 50 ꭥ and 0.1 ꭥ respectively. It is supplying a 2400 W load at a terminal voltage of 100 V. Calculate the total armature current, the current per armature path and the generated emf.
Synchronous Generator
In comparison to an asynchronous generator, it is a machine where the rotor speed is equal to the rotating magnetic field produced by the stator, i.e., mechanical speed is equal to the electrical speed, thus called synchronous, and not asynchronous.
Salient Pole Rotor
Salient pole rotor includes a large number of exposed poles mounted on a magnetic wheel. The construction of a bright pole is as shown in the image on the left. The proposed poles are made of metal laminations. The rotor winding is provided on these poles and is supported by pole shoes.
The field and armature resistance of a four-pole shunt generator with lap-connected armature is 50 ꭥ and 0.1 ꭥ respectively. It is supplying a 2400 W load at a terminal voltage of 100 V. Calculate the total armature current, the current per armature path and the generated emf.
Step by step
Solved in 2 steps with 2 images