Task-2 A radial feeder is shown in Figure 1. -3-Phase Transmission Line Bus-A Bus-B Bus-C Bus-D CB, CT CB, CTB CB.CTC 个 G .... 30MVA RA Re 11 kV Load-A Load-B Load-C Load-D 3MVA 7.5MVA 5.5MVA 6MVA Figure 1 Radial Feeder Time graded overcurrent protection scheme is to be designed for this feeder using Inverse Definite Minimum Time (IDMT) relays at all busses. The maximum fault current of 10000 Ampere and a minimum fault current of 4000 Ampere is expected to flow for three-phase fault and single line to ground fault, respectively, between bus C and D. IDMT relays located at all buses can be assumed to be of 1 Ampere OR 5 Ampere rating with 100% plug setting. Circuit breakers at bus B and C take 0.6 S to operate. Relay located at bus A has an overshoot time of 0.08 S while relay at bus B has an overshoot time of 0.1 S. The Time Setting Multiplier (TSM) QEAD- Template A Rev: 04_ ver 02 Date: 014 October 2018 Page 2 of 6 F/QAP/021/001 for the fastest relay is to be set to 0.5. Neglect the voltage drop in the line sections for the calculations. ASsume the Overload capacity of this feeder in the range of 20-35%. (i) Design appropriate CT ratios for CTA, CTB, and CTc. [06] (ii) Estimate time of Operation for all three relays for maximum value of fault current to maintain the selectivity. [06] (ii) Determine TSM for relays at bus A and B for maximum fault current. (Use the standard formula for IDMT relays for these calculations.) [06]
Task-2 A radial feeder is shown in Figure 1. -3-Phase Transmission Line Bus-A Bus-B Bus-C Bus-D CB, CT CB, CTB CB.CTC 个 G .... 30MVA RA Re 11 kV Load-A Load-B Load-C Load-D 3MVA 7.5MVA 5.5MVA 6MVA Figure 1 Radial Feeder Time graded overcurrent protection scheme is to be designed for this feeder using Inverse Definite Minimum Time (IDMT) relays at all busses. The maximum fault current of 10000 Ampere and a minimum fault current of 4000 Ampere is expected to flow for three-phase fault and single line to ground fault, respectively, between bus C and D. IDMT relays located at all buses can be assumed to be of 1 Ampere OR 5 Ampere rating with 100% plug setting. Circuit breakers at bus B and C take 0.6 S to operate. Relay located at bus A has an overshoot time of 0.08 S while relay at bus B has an overshoot time of 0.1 S. The Time Setting Multiplier (TSM) QEAD- Template A Rev: 04_ ver 02 Date: 014 October 2018 Page 2 of 6 F/QAP/021/001 for the fastest relay is to be set to 0.5. Neglect the voltage drop in the line sections for the calculations. ASsume the Overload capacity of this feeder in the range of 20-35%. (i) Design appropriate CT ratios for CTA, CTB, and CTc. [06] (ii) Estimate time of Operation for all three relays for maximum value of fault current to maintain the selectivity. [06] (ii) Determine TSM for relays at bus A and B for maximum fault current. (Use the standard formula for IDMT relays for these calculations.) [06]
Introductory Circuit Analysis (13th Edition)
13th Edition
ISBN:9780133923605
Author:Robert L. Boylestad
Publisher:Robert L. Boylestad
Chapter1: Introduction
Section: Chapter Questions
Problem 1P: Visit your local library (at school or home) and describe the extent to which it provides literature...
Related questions
Question
100%
Please I need step by step solution.
Expert Solution
This question has been solved!
Explore an expertly crafted, step-by-step solution for a thorough understanding of key concepts.
This is a popular solution!
Trending now
This is a popular solution!
Step by step
Solved in 5 steps with 4 images
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.Recommended textbooks for you
Introductory Circuit Analysis (13th Edition)
Electrical Engineering
ISBN:
9780133923605
Author:
Robert L. Boylestad
Publisher:
PEARSON
Delmar's Standard Textbook Of Electricity
Electrical Engineering
ISBN:
9781337900348
Author:
Stephen L. Herman
Publisher:
Cengage Learning
Programmable Logic Controllers
Electrical Engineering
ISBN:
9780073373843
Author:
Frank D. Petruzella
Publisher:
McGraw-Hill Education
Introductory Circuit Analysis (13th Edition)
Electrical Engineering
ISBN:
9780133923605
Author:
Robert L. Boylestad
Publisher:
PEARSON
Delmar's Standard Textbook Of Electricity
Electrical Engineering
ISBN:
9781337900348
Author:
Stephen L. Herman
Publisher:
Cengage Learning
Programmable Logic Controllers
Electrical Engineering
ISBN:
9780073373843
Author:
Frank D. Petruzella
Publisher:
McGraw-Hill Education
Fundamentals of Electric Circuits
Electrical Engineering
ISBN:
9780078028229
Author:
Charles K Alexander, Matthew Sadiku
Publisher:
McGraw-Hill Education
Electric Circuits. (11th Edition)
Electrical Engineering
ISBN:
9780134746968
Author:
James W. Nilsson, Susan Riedel
Publisher:
PEARSON
Engineering Electromagnetics
Electrical Engineering
ISBN:
9780078028151
Author:
Hayt, William H. (william Hart), Jr, BUCK, John A.
Publisher:
Mcgraw-hill Education,