Subtransient fault current in per-unit and in kA, per-unit L-G Voltage at bus 1?

Introductory Circuit Analysis (13th Edition)
13th Edition
ISBN:9780133923605
Author:Robert L. Boylestad
Publisher:Robert L. Boylestad
Chapter1: Introduction
Section: Chapter Questions
Problem 1P: Visit your local library (at school or home) and describe the extent to which it provides literature...
icon
Related questions
icon
Concept explainers
Question

Subtransient fault current in per-unit and in kA, per-unit L-G Voltage at bus 1?

Determine the subtransient fault current in per-unit and in kA, as well as the per-unit
line-to-ground voltages at the fault bus for a bolted single line-to-ground fault at the
fault bus selected in Problem 9.2.
Transcribed Image Text:Determine the subtransient fault current in per-unit and in kA, as well as the per-unit line-to-ground voltages at the fault bus for a bolted single line-to-ground fault at the fault bus selected in Problem 9.2.
The single-line diagram of a three-phase power system is shown in Figure 9.17.
Equipment ratings are given as follows:
Synchronous generators:
G1 1000 MVA
15 kV
1000 MVA
G2
G3 500 MVA
15 kV
13.8 kV
13.8 kV
G4 750 MVA
Transformers:
T1 1000 MVA
T2 1000 MVA
T3 500 MVA
T4 750 MVA
SYMMETRICAL FAULTS
Line 1-2
Transmission lines:
1-2 765 kV
1-3 765 kV
2-3 765 kV
15 kV A/765 kV Y
15 kV A/765 kV Y
15 kV Y/765 kV Y
15 kV Y/765 kV Y
₁²
◄
Line 1-3
2
2
X = X₂ = 0.18, Xo = 0.07 per unit
X = X₂ = 0.20, Xo = 0.10 per unit
X = X₂ = 0.15, Xo = 0.05 per unit
X = 0.30, X₂ = 0.40, Xo = 0.10 per unit
T₂
Line 2-3
X₁ = 50 £2, Xo = 150 2
X₁ = 40 92, Xo = 100 2
X₁ = 40 92, Xo = 100 2
X = 0.10 per unit
X = 0.10 per unit
X = 0.12 per unit
X = 0.11 per unit
3 T3
T₁
4
youthy
Transcribed Image Text:The single-line diagram of a three-phase power system is shown in Figure 9.17. Equipment ratings are given as follows: Synchronous generators: G1 1000 MVA 15 kV 1000 MVA G2 G3 500 MVA 15 kV 13.8 kV 13.8 kV G4 750 MVA Transformers: T1 1000 MVA T2 1000 MVA T3 500 MVA T4 750 MVA SYMMETRICAL FAULTS Line 1-2 Transmission lines: 1-2 765 kV 1-3 765 kV 2-3 765 kV 15 kV A/765 kV Y 15 kV A/765 kV Y 15 kV Y/765 kV Y 15 kV Y/765 kV Y ₁² ◄ Line 1-3 2 2 X = X₂ = 0.18, Xo = 0.07 per unit X = X₂ = 0.20, Xo = 0.10 per unit X = X₂ = 0.15, Xo = 0.05 per unit X = 0.30, X₂ = 0.40, Xo = 0.10 per unit T₂ Line 2-3 X₁ = 50 £2, Xo = 150 2 X₁ = 40 92, Xo = 100 2 X₁ = 40 92, Xo = 100 2 X = 0.10 per unit X = 0.10 per unit X = 0.12 per unit X = 0.11 per unit 3 T3 T₁ 4 youthy
Expert Solution
steps

Step by step

Solved in 10 steps with 13 images

Blurred answer
Knowledge Booster
Fault analysis
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Introductory Circuit Analysis (13th Edition)
Introductory Circuit Analysis (13th Edition)
Electrical Engineering
ISBN:
9780133923605
Author:
Robert L. Boylestad
Publisher:
PEARSON
Delmar's Standard Textbook Of Electricity
Delmar's Standard Textbook Of Electricity
Electrical Engineering
ISBN:
9781337900348
Author:
Stephen L. Herman
Publisher:
Cengage Learning
Programmable Logic Controllers
Programmable Logic Controllers
Electrical Engineering
ISBN:
9780073373843
Author:
Frank D. Petruzella
Publisher:
McGraw-Hill Education
Fundamentals of Electric Circuits
Fundamentals of Electric Circuits
Electrical Engineering
ISBN:
9780078028229
Author:
Charles K Alexander, Matthew Sadiku
Publisher:
McGraw-Hill Education
Electric Circuits. (11th Edition)
Electric Circuits. (11th Edition)
Electrical Engineering
ISBN:
9780134746968
Author:
James W. Nilsson, Susan Riedel
Publisher:
PEARSON
Engineering Electromagnetics
Engineering Electromagnetics
Electrical Engineering
ISBN:
9780078028151
Author:
Hayt, William H. (william Hart), Jr, BUCK, John A.
Publisher:
Mcgraw-hill Education,