Six 100Wp crystalline PV modules, each with an open circuit voltage (Voc) of 30V, are connected in series in a string. What would be the total open circuit voltage (Voc) of the string of modules? And what would be the total Wp of the string? 180V, 600Wp 180V, 100Wp 30V, 600Wp 30V, 100Wp The distance from a combiner box to a PV array junction box is 4 m. The voltage drop of the used cable on this distance is 0.5 V. The current is 8.0 A. What is the power loss on this distance? 16 W 32 A 4 W 2 W A PV system has a rated capacity of 10 kWp. The overall efficiency of this PV system is 75% . The average daily irradiance at the site is 4 kWh/m²/day. What is the expected average daily energy output of this system? 3 kWh 30 kWh 7.5 kWh 40 kWh
Six 100Wp crystalline PV modules, each with an open circuit voltage (Voc) of 30V, are connected in series in a string. What would be the total open circuit voltage (Voc) of the string of modules? And what would be the total Wp of the string?
180V, 600Wp
180V, 100Wp
30V, 600Wp
30V, 100Wp
The distance from a combiner box to a PV array junction box is 4 m.
The voltage drop of the used cable on this distance is 0.5 V.
The current is 8.0 A.
What is the power loss on this distance?
16 W
32 A
4 W
2 W
A PV system has a rated capacity of 10 kWp. The overall efficiency of this PV system is 75% . The average daily irradiance at the site is 4 kWh/m²/day. What is the expected average daily energy output of this system?
3 kWh
30 kWh
7.5 kWh
40 kWh