SITUATION. A composite beam is shown in the figure. The 10-meter long beam is a W16x40, A36 steel spaced 2-meters on-center and the concrete slab is 150 mm thick. Shear connectors ensure that there is a full composite action. -be- Properties of W16x40: A = 7612 mm² d = 410 mm x = 216 x 106 mm² Given: fy = 248 MPa ts = 130 mm fc = 21 MPa Nominal strength of each shear connector, Q₁ = 50 kN Strength-reduction factor, p = 0.90 TT I 1. Evaluate the effective flange width. 2. Compute the ultimate positive flexural strength of the composite section 3. Evaluate the required number of shear connectors.

Structural Analysis
6th Edition
ISBN:9781337630931
Author:KASSIMALI, Aslam.
Publisher:KASSIMALI, Aslam.
Chapter2: Loads On Structures
Section: Chapter Questions
Problem 1P
icon
Related questions
Question

show complete solution. need asap

SITUATION. A composite beam is shown in the figure. The 10-meter long beam
is a W16x40, A36 steel spaced 2-meters on-center and the concrete slab is 150
mm thick. Shear connectors ensure that there is a full composite action.
be-
Properties of W16x40:
A = 7612 mm²
d = 410 mm
T T
lx
= 216 x 106 mm4
Given:
I
fy = 248 MPa
ts = 130 mm
ay7.aghoring
fc = 21 MPa
Nominal strength of each
shear connector, Q₁ = 50 kN
Strength-reduction factor, p = 0.90
1.
Evaluate the effective flange width.
2.
Compute the ultimate positive flexural strength of the composite section
Evaluate the required number of shear connectors.
3.
Transcribed Image Text:SITUATION. A composite beam is shown in the figure. The 10-meter long beam is a W16x40, A36 steel spaced 2-meters on-center and the concrete slab is 150 mm thick. Shear connectors ensure that there is a full composite action. be- Properties of W16x40: A = 7612 mm² d = 410 mm T T lx = 216 x 106 mm4 Given: I fy = 248 MPa ts = 130 mm ay7.aghoring fc = 21 MPa Nominal strength of each shear connector, Q₁ = 50 kN Strength-reduction factor, p = 0.90 1. Evaluate the effective flange width. 2. Compute the ultimate positive flexural strength of the composite section Evaluate the required number of shear connectors. 3.
Expert Solution
trending now

Trending now

This is a popular solution!

steps

Step by step

Solved in 6 steps with 8 images

Blurred answer
Knowledge Booster
Composite construction
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, civil-engineering and related others by exploring similar questions and additional content below.
Recommended textbooks for you
Structural Analysis
Structural Analysis
Civil Engineering
ISBN:
9781337630931
Author:
KASSIMALI, Aslam.
Publisher:
Cengage,
Structural Analysis (10th Edition)
Structural Analysis (10th Edition)
Civil Engineering
ISBN:
9780134610672
Author:
Russell C. Hibbeler
Publisher:
PEARSON
Principles of Foundation Engineering (MindTap Cou…
Principles of Foundation Engineering (MindTap Cou…
Civil Engineering
ISBN:
9781337705028
Author:
Braja M. Das, Nagaratnam Sivakugan
Publisher:
Cengage Learning
Fundamentals of Structural Analysis
Fundamentals of Structural Analysis
Civil Engineering
ISBN:
9780073398006
Author:
Kenneth M. Leet Emeritus, Chia-Ming Uang, Joel Lanning
Publisher:
McGraw-Hill Education
Sustainable Energy
Sustainable Energy
Civil Engineering
ISBN:
9781337551663
Author:
DUNLAP, Richard A.
Publisher:
Cengage,
Traffic and Highway Engineering
Traffic and Highway Engineering
Civil Engineering
ISBN:
9781305156241
Author:
Garber, Nicholas J.
Publisher:
Cengage Learning