Several studies using Swiss railway workers have shown that exposure to time-varying magnetic fields with a frequency of 16.7 Hz, used in the Swiss railway system, can cause a significant decrease in melatonin production in the human body, which can then disrupt the circadian cycle and can also increase the incidence of leukemia in the exposed subjects. In one study, the careful measurement of magnetic fields at various heights at the location of the locomotive driver's seat detected an average magnetic field of magnitude 19.6 µT at the seated driver's head, 125 cm above the floor of the driver's compartment. The source of this magnetic field was found to be a power line that connected the 15 kV to 0.600 kV transformer, located at the front of the engine, to the electric motor located in the rear. If the power line connecting the transformer and the motor is a single cable 17.0 cm in diameter, including its insulation, running directly under the driver's seat and just below the floor, what is the current (in A) in the power line that will produce the measured magnetic field?

Introductory Circuit Analysis (13th Edition)
13th Edition
ISBN:9780133923605
Author:Robert L. Boylestad
Publisher:Robert L. Boylestad
Chapter1: Introduction
Section: Chapter Questions
Problem 1P: Visit your local library (at school or home) and describe the extent to which it provides literature...
icon
Related questions
Question
100%
no. 8 e
Question Details
SerPSE10 29 A OP.032 bio. [4143610|
Several studies using Swiss railway workers have shown that exposure to time-varying magnetic fields with a frequency of
16.7 Hz, used in the SwiSs railway system, can cause a significant decrease in melatonin production in the human body, which
can then disrupt the circadian cycle and can also increase the incidence of leukemia in the exposed subjects. In one study, the
careful measurement of magnetic fields at various heights at the location of the locomotive driver's seat detected an average
magnetic field of magnitude 19.6 uT at the seated driver's head, 125 cm above the floor of the driver's compartment. The
Source of this magnetic field was found to be a power line that connected the 15 kV to 0.600 kV transformer, located at the
front of the engine, to the electric motor located in the rear. If the power line connecting the transformer and the motor is a
single cable 17.0 cm in diameter, including its insulation, running directly under the driver's seat and just below the floor, what
is the current (in A) in the power line that will produce the measured magnetic field?
Transcribed Image Text:Question Details SerPSE10 29 A OP.032 bio. [4143610| Several studies using Swiss railway workers have shown that exposure to time-varying magnetic fields with a frequency of 16.7 Hz, used in the SwiSs railway system, can cause a significant decrease in melatonin production in the human body, which can then disrupt the circadian cycle and can also increase the incidence of leukemia in the exposed subjects. In one study, the careful measurement of magnetic fields at various heights at the location of the locomotive driver's seat detected an average magnetic field of magnitude 19.6 uT at the seated driver's head, 125 cm above the floor of the driver's compartment. The Source of this magnetic field was found to be a power line that connected the 15 kV to 0.600 kV transformer, located at the front of the engine, to the electric motor located in the rear. If the power line connecting the transformer and the motor is a single cable 17.0 cm in diameter, including its insulation, running directly under the driver's seat and just below the floor, what is the current (in A) in the power line that will produce the measured magnetic field?
Expert Solution
steps

Step by step

Solved in 2 steps

Blurred answer
Knowledge Booster
Magnetically Coupled Circuit
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.
Similar questions
Recommended textbooks for you
Introductory Circuit Analysis (13th Edition)
Introductory Circuit Analysis (13th Edition)
Electrical Engineering
ISBN:
9780133923605
Author:
Robert L. Boylestad
Publisher:
PEARSON
Delmar's Standard Textbook Of Electricity
Delmar's Standard Textbook Of Electricity
Electrical Engineering
ISBN:
9781337900348
Author:
Stephen L. Herman
Publisher:
Cengage Learning
Programmable Logic Controllers
Programmable Logic Controllers
Electrical Engineering
ISBN:
9780073373843
Author:
Frank D. Petruzella
Publisher:
McGraw-Hill Education
Fundamentals of Electric Circuits
Fundamentals of Electric Circuits
Electrical Engineering
ISBN:
9780078028229
Author:
Charles K Alexander, Matthew Sadiku
Publisher:
McGraw-Hill Education
Electric Circuits. (11th Edition)
Electric Circuits. (11th Edition)
Electrical Engineering
ISBN:
9780134746968
Author:
James W. Nilsson, Susan Riedel
Publisher:
PEARSON
Engineering Electromagnetics
Engineering Electromagnetics
Electrical Engineering
ISBN:
9780078028151
Author:
Hayt, William H. (william Hart), Jr, BUCK, John A.
Publisher:
Mcgraw-hill Education,