Sampling 4 pieces of precision-cut wire (to be used in computer assembly) every hour for the past 24 hours has produced the following results: X R 3.25" 0.76" 3.00 1.13 3.22 1.43 1.21 1.12 0.32 Hour X R Hour X R Hour 7 3.15" 0.48" 13 3.01" 0.90" 19 8 2.65 1.08 14 2.73 1.26 20 9 2.92 0.71 15 3.12 1.11 21 10 2.75 1.28 16 2.74 0.50 22 11 2.73 1.12 17 2.96 1.48 23 12 2.97 0.40 18 2.84 1.34 3.49 24 Hour 1 2 3 4 5 6 3.17 2.96 X R 1.56" 3.31" 2.79 2.55 1.09 1.08 3.18 0.46 2.84 1.58 2.54 0.92 D Based on the sampling done, the control limits for 3-sigma x chart are (round all intermediate calculations to three decimal places before proceeding with further calculations): Upper Control Limit (UCL) = 3.691 inches (round your response to three decimal places). Lower Control Limit (LCL-)= 2.215 inches (round your response to three decimal places). Based on the x-chart, the wire cutting process has been IN CONTROL The control limits for the 3-sigma R-chart are (round all intermediate calculations to three decimal places before proceeding with further calculations): Upper Control Limit (UCLR) = inches (round your response to three decimal places).
Sampling 4 pieces of precision-cut wire (to be used in computer assembly) every hour for the past 24 hours has produced the following results: X R 3.25" 0.76" 3.00 1.13 3.22 1.43 1.21 1.12 0.32 Hour X R Hour X R Hour 7 3.15" 0.48" 13 3.01" 0.90" 19 8 2.65 1.08 14 2.73 1.26 20 9 2.92 0.71 15 3.12 1.11 21 10 2.75 1.28 16 2.74 0.50 22 11 2.73 1.12 17 2.96 1.48 23 12 2.97 0.40 18 2.84 1.34 3.49 24 Hour 1 2 3 4 5 6 3.17 2.96 X R 1.56" 3.31" 2.79 2.55 1.09 1.08 3.18 0.46 2.84 1.58 2.54 0.92 D Based on the sampling done, the control limits for 3-sigma x chart are (round all intermediate calculations to three decimal places before proceeding with further calculations): Upper Control Limit (UCL) = 3.691 inches (round your response to three decimal places). Lower Control Limit (LCL-)= 2.215 inches (round your response to three decimal places). Based on the x-chart, the wire cutting process has been IN CONTROL The control limits for the 3-sigma R-chart are (round all intermediate calculations to three decimal places before proceeding with further calculations): Upper Control Limit (UCLR) = inches (round your response to three decimal places).
MATLAB: An Introduction with Applications
6th Edition
ISBN:9781119256830
Author:Amos Gilat
Publisher:Amos Gilat
Chapter1: Starting With Matlab
Section: Chapter Questions
Problem 1P
Related questions
Question
Expert Solution
This question has been solved!
Explore an expertly crafted, step-by-step solution for a thorough understanding of key concepts.
This is a popular solution!
Trending now
This is a popular solution!
Step by step
Solved in 4 steps with 18 images
Recommended textbooks for you
MATLAB: An Introduction with Applications
Statistics
ISBN:
9781119256830
Author:
Amos Gilat
Publisher:
John Wiley & Sons Inc
Probability and Statistics for Engineering and th…
Statistics
ISBN:
9781305251809
Author:
Jay L. Devore
Publisher:
Cengage Learning
Statistics for The Behavioral Sciences (MindTap C…
Statistics
ISBN:
9781305504912
Author:
Frederick J Gravetter, Larry B. Wallnau
Publisher:
Cengage Learning
MATLAB: An Introduction with Applications
Statistics
ISBN:
9781119256830
Author:
Amos Gilat
Publisher:
John Wiley & Sons Inc
Probability and Statistics for Engineering and th…
Statistics
ISBN:
9781305251809
Author:
Jay L. Devore
Publisher:
Cengage Learning
Statistics for The Behavioral Sciences (MindTap C…
Statistics
ISBN:
9781305504912
Author:
Frederick J Gravetter, Larry B. Wallnau
Publisher:
Cengage Learning
Elementary Statistics: Picturing the World (7th E…
Statistics
ISBN:
9780134683416
Author:
Ron Larson, Betsy Farber
Publisher:
PEARSON
The Basic Practice of Statistics
Statistics
ISBN:
9781319042578
Author:
David S. Moore, William I. Notz, Michael A. Fligner
Publisher:
W. H. Freeman
Introduction to the Practice of Statistics
Statistics
ISBN:
9781319013387
Author:
David S. Moore, George P. McCabe, Bruce A. Craig
Publisher:
W. H. Freeman