QUESTIONS 1. Why F.M. is less prone to noise than A.M.? 2. Which requires higher bandwidth FM or AM and why ? 3. What is the significance of higher 'Q' of the tuned circuit used for demodulation in detector

Introductory Circuit Analysis (13th Edition)
13th Edition
ISBN:9780133923605
Author:Robert L. Boylestad
Publisher:Robert L. Boylestad
Chapter1: Introduction
Section: Chapter Questions
Problem 1P: Visit your local library (at school or home) and describe the extent to which it provides literature...
icon
Related questions
Question
8/8
40502 - Frequency Modulation & Demodulation
Input
Peak to Peak
(Кеep
constant)
Output
Output
(Peak to Peak)
ratio
Sr. No.
Freq.
Input
1KHZ
2KHZ
3ΚHΖ
4KHZ
5KHZ
1.
2.
3.
4.
5.
40.
40KHZ
This is the frequency response curve of the slope detector. Compare it with Fig.5 and
comment on the suitability of thic clope detector for converting FM into Am signal.
QUESTIONS
Why F.M. is less prone to noise than A.M.?
2.
1.
Which requires higher bandwidth FM or AM and why ?
3. What is the significance of higher 'Q' of the tuned circuit used for demodulation in
slope
detector
circuit?
POWER SUPPLY
15-0-15 V At 100 mA
+12V at 100mA
78123
Gooma
C3
1uF
63V
C1
-T1000UF
35V
C2
+11000uF
35V
太太
D1 D2
Cov
GND
C4
1uF
63V
\św
D3 D4
279123
D1 - D4 =IN4001
COM.
-12V at 100mA
0 230V AC ± 10% AT50HZ
REFERENCES
1. Practical Electronics - Nov. 1974
ACCESSORIES
Patch cords stackable 4mm length 50cm Red-2.
Patch cords stackable 4mm leng
50cm black-2.
Tesca Technologies Pvt. Ltd.
www.tesca.in
Transcribed Image Text:8/8 40502 - Frequency Modulation & Demodulation Input Peak to Peak (Кеep constant) Output Output (Peak to Peak) ratio Sr. No. Freq. Input 1KHZ 2KHZ 3ΚHΖ 4KHZ 5KHZ 1. 2. 3. 4. 5. 40. 40KHZ This is the frequency response curve of the slope detector. Compare it with Fig.5 and comment on the suitability of thic clope detector for converting FM into Am signal. QUESTIONS Why F.M. is less prone to noise than A.M.? 2. 1. Which requires higher bandwidth FM or AM and why ? 3. What is the significance of higher 'Q' of the tuned circuit used for demodulation in slope detector circuit? POWER SUPPLY 15-0-15 V At 100 mA +12V at 100mA 78123 Gooma C3 1uF 63V C1 -T1000UF 35V C2 +11000uF 35V 太太 D1 D2 Cov GND C4 1uF 63V \św D3 D4 279123 D1 - D4 =IN4001 COM. -12V at 100mA 0 230V AC ± 10% AT50HZ REFERENCES 1. Practical Electronics - Nov. 1974 ACCESSORIES Patch cords stackable 4mm length 50cm Red-2. Patch cords stackable 4mm leng 50cm black-2. Tesca Technologies Pvt. Ltd. www.tesca.in
Expert Solution
steps

Step by step

Solved in 3 steps

Blurred answer
Knowledge Booster
Frequency Modulation
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.
Recommended textbooks for you
Introductory Circuit Analysis (13th Edition)
Introductory Circuit Analysis (13th Edition)
Electrical Engineering
ISBN:
9780133923605
Author:
Robert L. Boylestad
Publisher:
PEARSON
Delmar's Standard Textbook Of Electricity
Delmar's Standard Textbook Of Electricity
Electrical Engineering
ISBN:
9781337900348
Author:
Stephen L. Herman
Publisher:
Cengage Learning
Programmable Logic Controllers
Programmable Logic Controllers
Electrical Engineering
ISBN:
9780073373843
Author:
Frank D. Petruzella
Publisher:
McGraw-Hill Education
Fundamentals of Electric Circuits
Fundamentals of Electric Circuits
Electrical Engineering
ISBN:
9780078028229
Author:
Charles K Alexander, Matthew Sadiku
Publisher:
McGraw-Hill Education
Electric Circuits. (11th Edition)
Electric Circuits. (11th Edition)
Electrical Engineering
ISBN:
9780134746968
Author:
James W. Nilsson, Susan Riedel
Publisher:
PEARSON
Engineering Electromagnetics
Engineering Electromagnetics
Electrical Engineering
ISBN:
9780078028151
Author:
Hayt, William H. (william Hart), Jr, BUCK, John A.
Publisher:
Mcgraw-hill Education,