Question 3 G1 G2 T1 Figure 5: Single Line Diagram Table 2: Equipment specification Base MVA Voltage kV X1(p.u) X2(p.u) Xo(p.u) 0.05 0.05 Item G1 G2 100 20 0.15 0.15 0.15 0.10 0.10 0.125 0.125 100 20 0.15 0.10 T1 100 20/220 0.10 T2 100 100 20/220 0.10 0.10 Line 1-2 220 0.30 Line 1-3 Line 3-2 220 100 100 0.15 0.15 0.35 220 0.25 0.25 VĀ + 0.1 A single line diagram is shown in Figure 5 with their specification shown in Table 2. The neutral reactance 0.25 per unit is connected to each generator neutral, and value of A is in the range of 0.1 0.9. Single line-to-ground fault occurs at bus 3 with a fault impedance ZF = j0.1 per unit. Evaluate the fault current at bus 3, fault voltage at bus 3 and bus 2, and line fault current between bus 3 and bus 2 in per-unit value.

Introductory Circuit Analysis (13th Edition)
13th Edition
ISBN:9780133923605
Author:Robert L. Boylestad
Publisher:Robert L. Boylestad
Chapter1: Introduction
Section: Chapter Questions
Problem 1P: Visit your local library (at school or home) and describe the extent to which it provides literature...
icon
Related questions
icon
Concept explainers
Question

Full working and calculations please. Thank you 

Question 3
G1
G2
T1
T2
Figure 5: Single Line Diagram
Table 2: Equipment specification
Base MVA Voltage kV X1(p.u) X2(p.u)
100
100
Item
Xo(p.u)
G1
G2
20
0.15
0.15
0.05
20
0.15
0.15
0.05
T1
100
20/220
0.10
0.10
0.10
0.10
0.125 0.125
T2
20/220
0.10
0.10
100
100
Line 1-2
220
0.30
Line 1-3
100
220
0.15
0.15
0.35
Line 3-2
100
220
0.25
0.25
VĀ + 0.1
A single line diagram is shown in Figure 5 with their specification shown in Table 2.
The neutral reactance 0.25 per unit is connected to each generator neutral, and value
of A is in the range of 0.1 - 0.9. Single line-to-ground fault occurs at bus 3 with a fault
impedance ZF =
j0.1 per unit. Evaluate the fault current at bus 3, fault voltage at bus
3 and bus 2, and line fault current between bus 3 and bus 2 in per-unit value.
产产
Transcribed Image Text:Question 3 G1 G2 T1 T2 Figure 5: Single Line Diagram Table 2: Equipment specification Base MVA Voltage kV X1(p.u) X2(p.u) 100 100 Item Xo(p.u) G1 G2 20 0.15 0.15 0.05 20 0.15 0.15 0.05 T1 100 20/220 0.10 0.10 0.10 0.10 0.125 0.125 T2 20/220 0.10 0.10 100 100 Line 1-2 220 0.30 Line 1-3 100 220 0.15 0.15 0.35 Line 3-2 100 220 0.25 0.25 VĀ + 0.1 A single line diagram is shown in Figure 5 with their specification shown in Table 2. The neutral reactance 0.25 per unit is connected to each generator neutral, and value of A is in the range of 0.1 - 0.9. Single line-to-ground fault occurs at bus 3 with a fault impedance ZF = j0.1 per unit. Evaluate the fault current at bus 3, fault voltage at bus 3 and bus 2, and line fault current between bus 3 and bus 2 in per-unit value. 产产
Expert Solution
trending now

Trending now

This is a popular solution!

steps

Step by step

Solved in 4 steps with 5 images

Blurred answer
Knowledge Booster
Thermistors
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Introductory Circuit Analysis (13th Edition)
Introductory Circuit Analysis (13th Edition)
Electrical Engineering
ISBN:
9780133923605
Author:
Robert L. Boylestad
Publisher:
PEARSON
Delmar's Standard Textbook Of Electricity
Delmar's Standard Textbook Of Electricity
Electrical Engineering
ISBN:
9781337900348
Author:
Stephen L. Herman
Publisher:
Cengage Learning
Programmable Logic Controllers
Programmable Logic Controllers
Electrical Engineering
ISBN:
9780073373843
Author:
Frank D. Petruzella
Publisher:
McGraw-Hill Education
Fundamentals of Electric Circuits
Fundamentals of Electric Circuits
Electrical Engineering
ISBN:
9780078028229
Author:
Charles K Alexander, Matthew Sadiku
Publisher:
McGraw-Hill Education
Electric Circuits. (11th Edition)
Electric Circuits. (11th Edition)
Electrical Engineering
ISBN:
9780134746968
Author:
James W. Nilsson, Susan Riedel
Publisher:
PEARSON
Engineering Electromagnetics
Engineering Electromagnetics
Electrical Engineering
ISBN:
9780078028151
Author:
Hayt, William H. (william Hart), Jr, BUCK, John A.
Publisher:
Mcgraw-hill Education,