QUESTION 15 L1 Inputs o-S1 oo-S2 2 0-53 -S4 O True O False 1 o-S6 3 4 5- 0-S5 36 6 7 S1 36 S2 8 S3 SI S4 S5 HE S6 Ladder logic program TON TIMER ON DELAY Timer Time base Preset Accumulated MCR PL1 PL2 PL2 (MCR (MCR) T4:1 1:0 10 0 (DN) Outputs PL1 PL2 ¤ (MCR) Assuming the program has just been entered and the PLC is placed in the RUN mode with all switches turned off. With reference to the above program, if switches S2 and S3 are turned on. Outputs PL1 and PL2 come on. L2

Introductory Circuit Analysis (13th Edition)
13th Edition
ISBN:9780133923605
Author:Robert L. Boylestad
Publisher:Robert L. Boylestad
Chapter1: Introduction
Section: Chapter Questions
Problem 1P: Visit your local library (at school or home) and describe the extent to which it provides literature...
icon
Related questions
Question
Q15
With Reference to the above Ladder Logic Program.
Assume all switches are turned off after each operation.
Assume all switches are turned off. In what order will the rungs be scanned?
O 1,2,3,4,5,6,7,8,9,10
O 1,2,11,12,14,15,3,9,10
O None of the above
QUESTION 15
L1
Inputs
o-S1
0-53
o 0-S4
15
o-S2 2
-0-55
O True
O False
1
3
4
oo-S6 5+
6
8
S1
36
S2
S3
S4
36
S5
36
S6
HH
Ladder logic program
RET
RETURN
TON-
TIMER ON DELAY
Timer
Time base
Preset
Accumulated
() ) 20 20 (5)
PL1
PL2
PL2
(MCR)
(MCR
(EN)
T4:1
1:0 (ON)
10
0
Outputs
PL1
-0-
PL2
(MCR)
Assuming the program has just been entered and the PLC is placed in the RUN mode with all switches turned off.
With reference to the above program, if switches S2 and S3 are turned on. Outputs PL1 and PL2 come on.
L2
Click Save and Submit to save and submit. Click Save All Answers to save all answers.
Transcribed Image Text:With Reference to the above Ladder Logic Program. Assume all switches are turned off after each operation. Assume all switches are turned off. In what order will the rungs be scanned? O 1,2,3,4,5,6,7,8,9,10 O 1,2,11,12,14,15,3,9,10 O None of the above QUESTION 15 L1 Inputs o-S1 0-53 o 0-S4 15 o-S2 2 -0-55 O True O False 1 3 4 oo-S6 5+ 6 8 S1 36 S2 S3 S4 36 S5 36 S6 HH Ladder logic program RET RETURN TON- TIMER ON DELAY Timer Time base Preset Accumulated () ) 20 20 (5) PL1 PL2 PL2 (MCR) (MCR (EN) T4:1 1:0 (ON) 10 0 Outputs PL1 -0- PL2 (MCR) Assuming the program has just been entered and the PLC is placed in the RUN mode with all switches turned off. With reference to the above program, if switches S2 and S3 are turned on. Outputs PL1 and PL2 come on. L2 Click Save and Submit to save and submit. Click Save All Answers to save all answers.
Expert Solution
steps

Step by step

Solved in 2 steps

Blurred answer
Knowledge Booster
Logic Gate and Its Application
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.
Recommended textbooks for you
Introductory Circuit Analysis (13th Edition)
Introductory Circuit Analysis (13th Edition)
Electrical Engineering
ISBN:
9780133923605
Author:
Robert L. Boylestad
Publisher:
PEARSON
Delmar's Standard Textbook Of Electricity
Delmar's Standard Textbook Of Electricity
Electrical Engineering
ISBN:
9781337900348
Author:
Stephen L. Herman
Publisher:
Cengage Learning
Programmable Logic Controllers
Programmable Logic Controllers
Electrical Engineering
ISBN:
9780073373843
Author:
Frank D. Petruzella
Publisher:
McGraw-Hill Education
Fundamentals of Electric Circuits
Fundamentals of Electric Circuits
Electrical Engineering
ISBN:
9780078028229
Author:
Charles K Alexander, Matthew Sadiku
Publisher:
McGraw-Hill Education
Electric Circuits. (11th Edition)
Electric Circuits. (11th Edition)
Electrical Engineering
ISBN:
9780134746968
Author:
James W. Nilsson, Susan Riedel
Publisher:
PEARSON
Engineering Electromagnetics
Engineering Electromagnetics
Electrical Engineering
ISBN:
9780078028151
Author:
Hayt, William H. (william Hart), Jr, BUCK, John A.
Publisher:
Mcgraw-hill Education,