QUESTION 10 A squirrel cage induction motor's nameplate values are 2.5 kW, 380 V, 3 phase, 50 Hz, Isn=5 A, 1460 rpm, 4 poles. When the motor is working at no-load operation, it draws 40% of the rated (full load current) from the grid. While and Pfv-0,05 Pin Eind the reactive powers while the motor draws during no-load operation. A. 1000 B. 1442.1 OC 1311 O D. 1376 O E. 1460 QUESTION 11 A star-connected three-phase cylindrical rotor synchronous generator of 1000 kVA with a phase-to-phase voltage of 4600 V, resistance per phase Rg 2 /phase, the synchronous reactance per phase Xg 20 /phase. At rated load current; a. Unity power factor (ohmic), Find the values of induced voltages. OA 3153,45 V O B. 5462 V O C. 3840.67 V D. 4961,29 W

Introductory Circuit Analysis (13th Edition)
13th Edition
ISBN:9780133923605
Author:Robert L. Boylestad
Publisher:Robert L. Boylestad
Chapter1: Introduction
Section: Chapter Questions
Problem 1P: Visit your local library (at school or home) and describe the extent to which it provides literature...
icon
Related questions
Question
QUESTION 10
A squirrel cage induction motor's nameplate values are 2.5 kW, 380 V, 3 phase, 50 Hz, Isn=5 A, 1460 rpm, 4 poles.
When the motor is working at no-load operation, it draws 40% of the rated (full load current) from the grid. While and
Pfv-0,05 Pin Eind the reactive powers while the motor draws during no-load operation.
OA 1000
B. 1442.1
OC 1311
D. 1376
O E. 1460
QUESTION 11
A star-connected three-phase cylindrical rotor synchronous generator of 1000 kVA with a phase-to-phase voltage of
4600 V, resistance per phase Rg = 2 N/phase, the synchronous reactance per phase Xg = 20 phase. At rated load
current;
a. Unity power factor (ohmic),
Find the values of induced voltages.
OA 3153,45 V
B. 5462 V
C. 3840.67 V
O D. 4961,29 W
Transcribed Image Text:QUESTION 10 A squirrel cage induction motor's nameplate values are 2.5 kW, 380 V, 3 phase, 50 Hz, Isn=5 A, 1460 rpm, 4 poles. When the motor is working at no-load operation, it draws 40% of the rated (full load current) from the grid. While and Pfv-0,05 Pin Eind the reactive powers while the motor draws during no-load operation. OA 1000 B. 1442.1 OC 1311 D. 1376 O E. 1460 QUESTION 11 A star-connected three-phase cylindrical rotor synchronous generator of 1000 kVA with a phase-to-phase voltage of 4600 V, resistance per phase Rg = 2 N/phase, the synchronous reactance per phase Xg = 20 phase. At rated load current; a. Unity power factor (ohmic), Find the values of induced voltages. OA 3153,45 V B. 5462 V C. 3840.67 V O D. 4961,29 W
Expert Solution
steps

Step by step

Solved in 2 steps

Blurred answer
Knowledge Booster
Three phase Induction Motor
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.
Recommended textbooks for you
Introductory Circuit Analysis (13th Edition)
Introductory Circuit Analysis (13th Edition)
Electrical Engineering
ISBN:
9780133923605
Author:
Robert L. Boylestad
Publisher:
PEARSON
Delmar's Standard Textbook Of Electricity
Delmar's Standard Textbook Of Electricity
Electrical Engineering
ISBN:
9781337900348
Author:
Stephen L. Herman
Publisher:
Cengage Learning
Programmable Logic Controllers
Programmable Logic Controllers
Electrical Engineering
ISBN:
9780073373843
Author:
Frank D. Petruzella
Publisher:
McGraw-Hill Education
Fundamentals of Electric Circuits
Fundamentals of Electric Circuits
Electrical Engineering
ISBN:
9780078028229
Author:
Charles K Alexander, Matthew Sadiku
Publisher:
McGraw-Hill Education
Electric Circuits. (11th Edition)
Electric Circuits. (11th Edition)
Electrical Engineering
ISBN:
9780134746968
Author:
James W. Nilsson, Susan Riedel
Publisher:
PEARSON
Engineering Electromagnetics
Engineering Electromagnetics
Electrical Engineering
ISBN:
9780078028151
Author:
Hayt, William H. (william Hart), Jr, BUCK, John A.
Publisher:
Mcgraw-hill Education,