QUESTION 1:- (a)    A 4-pole, 3-phase, star-connected, 50 Hz synchronous generator, with a synchronous impedance of j24.5 Ω/phase and negligible resistance, delivers 5 MW of power to a 13.8 kV busbar. At this operating point, the excitation is equal to 1.8 p.u. Calculate the phase value of the generated emf (E) and hence calculate the electrical load angle, δ, at which the machine is operating.

Introductory Circuit Analysis (13th Edition)
13th Edition
ISBN:9780133923605
Author:Robert L. Boylestad
Publisher:Robert L. Boylestad
Chapter1: Introduction
Section: Chapter Questions
Problem 1P: Visit your local library (at school or home) and describe the extent to which it provides literature...
icon
Related questions
Question

QUESTION 1:-

(a)    A 4-pole, 3-phase, star-connected, 50 Hz synchronous generator, with a synchronous impedance of j24.5 Ω/phase and negligible resistance, delivers 5 MW of power to a 13.8 kV busbar. At this operating point, the excitation is equal to 1.8 p.u. Calculate the phase value of the generated emf (E) and hence calculate the electrical load angle, δ, at which the machine is operating.


(b)    Sketch a typical operating chart for a salient pole synchronous generator and on the chart identify the following;

  •  The Apparent Power limit,
  • The field (excitation) limit,
  • The Real Power limit,
  • A line which represents a constant lagging power factor, The rotor angle for operation at any given point of operation, e.g.
  • rated power and 0.9 power factor lag.

(c)    A Stamford HCI534F framesize generator has been selected for a stand-alone diesel-generation application. The generator is to operate at 400 V, 50 Hz, with the self-excited (SX) excitation scheme. Datasheet information can be found in Appendix 1.

  1.  If a load of 268 kVA, 0.8 lag power factor is applied to the generator, determine the efficiency at which it will operate and hence calculate the engine size required, in kW.
  2.  A 400 V, 50 Hz, 57 kW motor is to be started DOL from the generator. The motor’s efficiency is 90.3% and its running power factor is 0.85 lag. Determine what % transient voltage-dip will be experienced by the generator as the motor starts.
Expert Solution
steps

Step by step

Solved in 4 steps with 1 images

Blurred answer
Knowledge Booster
Stability Analysis in Power System
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.
Similar questions
Recommended textbooks for you
Introductory Circuit Analysis (13th Edition)
Introductory Circuit Analysis (13th Edition)
Electrical Engineering
ISBN:
9780133923605
Author:
Robert L. Boylestad
Publisher:
PEARSON
Delmar's Standard Textbook Of Electricity
Delmar's Standard Textbook Of Electricity
Electrical Engineering
ISBN:
9781337900348
Author:
Stephen L. Herman
Publisher:
Cengage Learning
Programmable Logic Controllers
Programmable Logic Controllers
Electrical Engineering
ISBN:
9780073373843
Author:
Frank D. Petruzella
Publisher:
McGraw-Hill Education
Fundamentals of Electric Circuits
Fundamentals of Electric Circuits
Electrical Engineering
ISBN:
9780078028229
Author:
Charles K Alexander, Matthew Sadiku
Publisher:
McGraw-Hill Education
Electric Circuits. (11th Edition)
Electric Circuits. (11th Edition)
Electrical Engineering
ISBN:
9780134746968
Author:
James W. Nilsson, Susan Riedel
Publisher:
PEARSON
Engineering Electromagnetics
Engineering Electromagnetics
Electrical Engineering
ISBN:
9780078028151
Author:
Hayt, William H. (william Hart), Jr, BUCK, John A.
Publisher:
Mcgraw-hill Education,