QI/A- Chose the correct answer with explanation 1- A 3-phase 440 V, 50 Hz induction motor has 4% slip. The frequency of rotor current will be A- 50Hz B- 25Hz C- SHz D- 2Hz) 2- A three phase, 50 Hz, 4-pole induction motor has a full load speed of 1440 rpm. The full load slip will be A- 3% B- 5% C-4% D- 2% 3- An eight-pole wound rotor induction motor operating on 60 Hz supply is driven at 1800 rpm by a prime mover in the opposite direction of revolving magnetic field. The frequency of rotor current is A- 120 Hz B- 180 Hz D-200 Hz C- 160 Hz

Introductory Circuit Analysis (13th Edition)
13th Edition
ISBN:9780133923605
Author:Robert L. Boylestad
Publisher:Robert L. Boylestad
Chapter1: Introduction
Section: Chapter Questions
Problem 1P: Visit your local library (at school or home) and describe the extent to which it provides literature...
icon
Related questions
Question
QI/A- Chose the correct answer with explanation
1- A 3-phase 440 V, 50 Hz induction motor has 4% slip. The frequency of rotor current will
be
A- 50Hz
B- 25Hz
C- SHz
D- 2Hz )
2- A three phase, 50 Hz, 4-pole induction motor has a full load speed of 1440 rpm. The full
load slip will be
A- 3%
B- 5%
> C-4% (
D- 2%
3- An eight-pole wound rotor induction motor operating on 60 Hz supply is driven at 1800
rpm by a prime mover in the opposite direction of revolving magnetic field. The
frequency of rotor current is
A- 120 Hz
B- 180 Hz
C-160 Hz
D-200 Hz
4- The rotor power output of a 3-phase induction motor is 30 KW and corresponding slip is
4%. The rotor copper loss will be
A-625 Watt B-250 Watt
D- 1250 Watt
C-1000 Watt
20 hm Its equi alent
Transcribed Image Text:QI/A- Chose the correct answer with explanation 1- A 3-phase 440 V, 50 Hz induction motor has 4% slip. The frequency of rotor current will be A- 50Hz B- 25Hz C- SHz D- 2Hz ) 2- A three phase, 50 Hz, 4-pole induction motor has a full load speed of 1440 rpm. The full load slip will be A- 3% B- 5% > C-4% ( D- 2% 3- An eight-pole wound rotor induction motor operating on 60 Hz supply is driven at 1800 rpm by a prime mover in the opposite direction of revolving magnetic field. The frequency of rotor current is A- 120 Hz B- 180 Hz C-160 Hz D-200 Hz 4- The rotor power output of a 3-phase induction motor is 30 KW and corresponding slip is 4%. The rotor copper loss will be A-625 Watt B-250 Watt D- 1250 Watt C-1000 Watt 20 hm Its equi alent
Expert Solution
steps

Step by step

Solved in 4 steps

Blurred answer
Knowledge Booster
Winding and Construction of the Rotor and Stator
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.
Similar questions
Recommended textbooks for you
Introductory Circuit Analysis (13th Edition)
Introductory Circuit Analysis (13th Edition)
Electrical Engineering
ISBN:
9780133923605
Author:
Robert L. Boylestad
Publisher:
PEARSON
Delmar's Standard Textbook Of Electricity
Delmar's Standard Textbook Of Electricity
Electrical Engineering
ISBN:
9781337900348
Author:
Stephen L. Herman
Publisher:
Cengage Learning
Programmable Logic Controllers
Programmable Logic Controllers
Electrical Engineering
ISBN:
9780073373843
Author:
Frank D. Petruzella
Publisher:
McGraw-Hill Education
Fundamentals of Electric Circuits
Fundamentals of Electric Circuits
Electrical Engineering
ISBN:
9780078028229
Author:
Charles K Alexander, Matthew Sadiku
Publisher:
McGraw-Hill Education
Electric Circuits. (11th Edition)
Electric Circuits. (11th Edition)
Electrical Engineering
ISBN:
9780134746968
Author:
James W. Nilsson, Susan Riedel
Publisher:
PEARSON
Engineering Electromagnetics
Engineering Electromagnetics
Electrical Engineering
ISBN:
9780078028151
Author:
Hayt, William H. (william Hart), Jr, BUCK, John A.
Publisher:
Mcgraw-hill Education,