QI. Power and Power Factor Correction A factory has the following five major loads: Load 1: A motor rated at 4 Hp,0.85 pf lagging ( 1 hp = 0.7457kW) Load 2: A heater rated 3 kW at unity power factor Load 3: A synchronous motor rated at 3kVar, 0.85 pf leading Load 4: Thirtyty - 100-W lightbulbs Load 5: A motor rated 2.5 Hp at 0.85 pf leading a) Calculate the total real, reactive and apparent power. b) Find the overall power factor. c) the Kvar rating and capacitance required to improve the power factor to unity. d.) the current drawn from the supply under the new power factor conditions.

Delmar's Standard Textbook Of Electricity
7th Edition
ISBN:9781337900348
Author:Stephen L. Herman
Publisher:Stephen L. Herman
Chapter26: Three-phase Circuits
Section: Chapter Questions
Problem 3PA: You are an electrician working in an industrial plant. A 30-hp three-phase induction motor has a...
icon
Related questions
Question
QI. Power and Power Factor Correction
A factory has the following five major loads:
Load 1: A motor rated at 4 Hp,0.85 pf lagging ( 1 hp = 0.7457kW)
Load 2: A heater rated 3 kW at unity power factor
Load 3: A synchronous motor rated at 3kVar, 0.85 pf leading
Load 4: Thirtyty - 100-W lightbulbs
Load 5: A motor rated 2.5 Hp at 0.85 pf leading
a) Calculate the total real, reactive and apparent power.
b) Find the overall power factor.
c) the Kvar rating and capacitance required to improve the power
factor to unity.
d.) the current drawn from the supply under the new power factor
conditions.
Transcribed Image Text:QI. Power and Power Factor Correction A factory has the following five major loads: Load 1: A motor rated at 4 Hp,0.85 pf lagging ( 1 hp = 0.7457kW) Load 2: A heater rated 3 kW at unity power factor Load 3: A synchronous motor rated at 3kVar, 0.85 pf leading Load 4: Thirtyty - 100-W lightbulbs Load 5: A motor rated 2.5 Hp at 0.85 pf leading a) Calculate the total real, reactive and apparent power. b) Find the overall power factor. c) the Kvar rating and capacitance required to improve the power factor to unity. d.) the current drawn from the supply under the new power factor conditions.
Expert Solution
steps

Step by step

Solved in 5 steps with 5 images

Blurred answer
Knowledge Booster
Three phase Induction Motor
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Delmar's Standard Textbook Of Electricity
Delmar's Standard Textbook Of Electricity
Electrical Engineering
ISBN:
9781337900348
Author:
Stephen L. Herman
Publisher:
Cengage Learning
Power System Analysis and Design (MindTap Course …
Power System Analysis and Design (MindTap Course …
Electrical Engineering
ISBN:
9781305632134
Author:
J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:
Cengage Learning
Electricity for Refrigeration, Heating, and Air C…
Electricity for Refrigeration, Heating, and Air C…
Mechanical Engineering
ISBN:
9781337399128
Author:
Russell E. Smith
Publisher:
Cengage Learning