Q6: Consider a 3 bedroom apartment with 3 roommates. The apartment has a volume of 11,742 m^3 with 3 meter ceilings. If the apartment was ventilated according to the requirements of ASHRAE 62.2, what would the CO2 concentration be inside the house when all the roommates are home? Assume the outdoor concentration is 400ppm, the CO2 generation rate is .005 L/SCO2/person, and 100% outdoor air is used with no recirculation.

Structural Analysis
6th Edition
ISBN:9781337630931
Author:KASSIMALI, Aslam.
Publisher:KASSIMALI, Aslam.
Chapter2: Loads On Structures
Section: Chapter Questions
Problem 1P
icon
Related questions
Question
Determining Whole-Building Ventilation Rates for Residential Buildings
Whole-building ventilation replaces an amount of stale, indoor air with ventilation from the outdoors. It is
intended to dilute indoor pollutants and provide acceptable air quality. ASHRAE Standard 62.2, Ventilation and
Acceptable Air Quality in Low-Rise Residential Buildings, defines the roles and minimum requirements for
mechanical systems, natural ventilation systems, and building envelopes intended to provide acceptable
indoor air quality (IAQ) in residential buildings. We will use the following formula from ASHRAE Standard 62.2
to calculate the total required ventilation rate:
Q = 0.15A floor + 3.5 (Nhr + 1)
Where:
Q is the total required ventilation rate (L/s)
A floor is the dwelling-unit floor area (m2)
Nbris the number of bedrooms (not to be less than 1)
Once we know the ventilation rate in a space of a given volume, we can also calculate the steady-state CO2
concentration using the following formula:
GNK
Cin
Cout +
Q
Where:
Cin is the indoor steady state concentration of CO2, expressed as parts per million, or ppm
(dimensionless)
Cout is the outdoor concentration of CO2 that is in the fresh air from outdoors, expressed as parts per
million, or ppm (dimensionless)
G is the generation rate of CO2 per occupant (L/s of CO2/ person)
N is the number of occupants (people)
O is the total ventilation rate (L/s)
K is a constant to introduce units of ppm (K is equal to 1,000,000)
Transcribed Image Text:Determining Whole-Building Ventilation Rates for Residential Buildings Whole-building ventilation replaces an amount of stale, indoor air with ventilation from the outdoors. It is intended to dilute indoor pollutants and provide acceptable air quality. ASHRAE Standard 62.2, Ventilation and Acceptable Air Quality in Low-Rise Residential Buildings, defines the roles and minimum requirements for mechanical systems, natural ventilation systems, and building envelopes intended to provide acceptable indoor air quality (IAQ) in residential buildings. We will use the following formula from ASHRAE Standard 62.2 to calculate the total required ventilation rate: Q = 0.15A floor + 3.5 (Nhr + 1) Where: Q is the total required ventilation rate (L/s) A floor is the dwelling-unit floor area (m2) Nbris the number of bedrooms (not to be less than 1) Once we know the ventilation rate in a space of a given volume, we can also calculate the steady-state CO2 concentration using the following formula: GNK Cin Cout + Q Where: Cin is the indoor steady state concentration of CO2, expressed as parts per million, or ppm (dimensionless) Cout is the outdoor concentration of CO2 that is in the fresh air from outdoors, expressed as parts per million, or ppm (dimensionless) G is the generation rate of CO2 per occupant (L/s of CO2/ person) N is the number of occupants (people) O is the total ventilation rate (L/s) K is a constant to introduce units of ppm (K is equal to 1,000,000)
Q6: Consider a 3 bedroom apartment with 3
roommates. The apartment has a volume of
11,742 m^3 with 3 meter ceilings. If the
apartment was ventilated according to the
requirements of ASHRAE 62.2, what would
the CO2 concentration be inside the house
when all the roommates are home? Assume
the outdoor concentration is 400ppm, the
CO2 generation rate is .005 L/sCO2/person,
and 100% outdoor air is used with no
recirculation.
Transcribed Image Text:Q6: Consider a 3 bedroom apartment with 3 roommates. The apartment has a volume of 11,742 m^3 with 3 meter ceilings. If the apartment was ventilated according to the requirements of ASHRAE 62.2, what would the CO2 concentration be inside the house when all the roommates are home? Assume the outdoor concentration is 400ppm, the CO2 generation rate is .005 L/sCO2/person, and 100% outdoor air is used with no recirculation.
Expert Solution
trending now

Trending now

This is a popular solution!

steps

Step by step

Solved in 5 steps with 5 images

Blurred answer
Knowledge Booster
Interior finishes for wood light frame construction
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, civil-engineering and related others by exploring similar questions and additional content below.
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Structural Analysis
Structural Analysis
Civil Engineering
ISBN:
9781337630931
Author:
KASSIMALI, Aslam.
Publisher:
Cengage,
Structural Analysis (10th Edition)
Structural Analysis (10th Edition)
Civil Engineering
ISBN:
9780134610672
Author:
Russell C. Hibbeler
Publisher:
PEARSON
Principles of Foundation Engineering (MindTap Cou…
Principles of Foundation Engineering (MindTap Cou…
Civil Engineering
ISBN:
9781337705028
Author:
Braja M. Das, Nagaratnam Sivakugan
Publisher:
Cengage Learning
Fundamentals of Structural Analysis
Fundamentals of Structural Analysis
Civil Engineering
ISBN:
9780073398006
Author:
Kenneth M. Leet Emeritus, Chia-Ming Uang, Joel Lanning
Publisher:
McGraw-Hill Education
Sustainable Energy
Sustainable Energy
Civil Engineering
ISBN:
9781337551663
Author:
DUNLAP, Richard A.
Publisher:
Cengage,
Traffic and Highway Engineering
Traffic and Highway Engineering
Civil Engineering
ISBN:
9781305156241
Author:
Garber, Nicholas J.
Publisher:
Cengage Learning