Q4: are lots of In many industries or plants, there a manual water filling systems are used for water storage as shown, where the feed valve (MV1) is used for the tank filling cycle and the discharge valve (MV2) for the tank emptying cycle. Both will be controlled according to sensors. So when the water level drops below low level, the feed valve will turn on automatically and when the water level reaches high level and is sensed by the high level sensor, the system will wait for 1 minute and then empty automatically. Also when high level is detected, it will turn on Bell for alert purpose. The cycle will stop if the user presses the stop button on the control panel. TLB 1C TLB 2 D MV1 R (25 Marks) Tank START STOP INDICATION Reset Buzzer MV2

Electric Motor Control
10th Edition
ISBN:9781133702818
Author:Herman
Publisher:Herman
Chapter7: Relays
Section: Chapter Questions
Problem 9SQ: What is optoisolation?
icon
Related questions
Question
Q4:
are
lots of
In many industries or plants, there a
manual water filling systems are used for
water storage as shown, where the feed valve
(MV1) is used for the tank filling cycle and
the discharge valve (MV2) for the tank
emptying cycle. Both will be controlled
according to sensors. So when the water level
drops below low level, the feed valve will
turn on automatically and when the water
level reaches high level and is sensed by the
high level sensor, the system will wait for 1
minute and then empty automatically. Also
when high level is detected, it will turn on
Bell for alert purpose. The cycle will stop if
the user presses the stop button on the control
panel.
TLB 1C
TLB 2 D
MV1
R
(25 Marks)
Tank
START
STOP
INDICATION
Reset
Buzzer
MV2
Transcribed Image Text:Q4: are lots of In many industries or plants, there a manual water filling systems are used for water storage as shown, where the feed valve (MV1) is used for the tank filling cycle and the discharge valve (MV2) for the tank emptying cycle. Both will be controlled according to sensors. So when the water level drops below low level, the feed valve will turn on automatically and when the water level reaches high level and is sensed by the high level sensor, the system will wait for 1 minute and then empty automatically. Also when high level is detected, it will turn on Bell for alert purpose. The cycle will stop if the user presses the stop button on the control panel. TLB 1C TLB 2 D MV1 R (25 Marks) Tank START STOP INDICATION Reset Buzzer MV2
Expert Solution
steps

Step by step

Solved in 2 steps

Blurred answer
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Electric Motor Control
Electric Motor Control
Electrical Engineering
ISBN:
9781133702818
Author:
Herman
Publisher:
CENGAGE L
EBK ELECTRICAL WIRING RESIDENTIAL
EBK ELECTRICAL WIRING RESIDENTIAL
Electrical Engineering
ISBN:
9781337516549
Author:
Simmons
Publisher:
CENGAGE LEARNING - CONSIGNMENT
Electricity for Refrigeration, Heating, and Air C…
Electricity for Refrigeration, Heating, and Air C…
Mechanical Engineering
ISBN:
9781337399128
Author:
Russell E. Smith
Publisher:
Cengage Learning