Q3/A/ For the three bus power system shown in Fig.(3), all the per unit reactances of its elements are scaled on a common MVA base and they are given as follow: G: 25 MVA, 11 kV, Xa =0.12p.u. M: 25 MVA, 6.6 kV, Xa =0.3 p.u. T1: 25 MVA, 11/66 kV, X= 0.09 p.u. T2: 25 MVA, 6.6/66 kV, X=0.08 p.u. T3: 25 MVA, 6.6/66 kV, X=0.08 p.u. Linel: 66 kV,X=0.2 pu: Line2: 66 kV, X=0.1 p.u. Bus 1 Bus 2 Bus 3 T2 Bus 4 Line 1 M uw T, Bus 5 Symmetrical three phase fault Line 2 Fig. (3) Bus 6 For a symmetrical three phase fault occurs at point F( at the mid point of line 1), find the fault current in amperes?

Introductory Circuit Analysis (13th Edition)
13th Edition
ISBN:9780133923605
Author:Robert L. Boylestad
Publisher:Robert L. Boylestad
Chapter1: Introduction
Section: Chapter Questions
Problem 1P: Visit your local library (at school or home) and describe the extent to which it provides literature...
icon
Related questions
Question
i need ans within 15 minutes my best wishes ton
Q3/A/ For the three bus power system shown in Fig.(3), all the per unit reactances of its elements are
scaled on a common MVA base and they are given as follow:
G: 25 MVA, 11 kV, Xa =0.12p.u.
M: 25 MVA, 6.6 kV, Xa =0.3 p.u.
T: 25 MVA, 11/66 kV, X= 0.09 p.u.
T2: 25 MVA, 6.6/66 kV, X=0.08 p.u.
T3: 25 MVA, 6.6/66 kV, X=0.08 p.u.
Linel: 66 kV,X=0.2 pu:
Line2: 66 kV, X-0.1 p.u.
Bus 1
Bus 2
Bus 3
T2
Bus 4
Line 1
F
M
uw T3
Bus 5
Symmetrical
three phase fault
Line 2
Fig. (3)
Bus 6
For a symmetrical three phase fault occurs at point F( at the mid point of line 1), find the fault current
in amperes?
Transcribed Image Text:Q3/A/ For the three bus power system shown in Fig.(3), all the per unit reactances of its elements are scaled on a common MVA base and they are given as follow: G: 25 MVA, 11 kV, Xa =0.12p.u. M: 25 MVA, 6.6 kV, Xa =0.3 p.u. T: 25 MVA, 11/66 kV, X= 0.09 p.u. T2: 25 MVA, 6.6/66 kV, X=0.08 p.u. T3: 25 MVA, 6.6/66 kV, X=0.08 p.u. Linel: 66 kV,X=0.2 pu: Line2: 66 kV, X-0.1 p.u. Bus 1 Bus 2 Bus 3 T2 Bus 4 Line 1 F M uw T3 Bus 5 Symmetrical three phase fault Line 2 Fig. (3) Bus 6 For a symmetrical three phase fault occurs at point F( at the mid point of line 1), find the fault current in amperes?
Expert Solution
steps

Step by step

Solved in 3 steps with 3 images

Blurred answer
Knowledge Booster
Diode-Transistor Logic Circuit
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.
Recommended textbooks for you
Introductory Circuit Analysis (13th Edition)
Introductory Circuit Analysis (13th Edition)
Electrical Engineering
ISBN:
9780133923605
Author:
Robert L. Boylestad
Publisher:
PEARSON
Delmar's Standard Textbook Of Electricity
Delmar's Standard Textbook Of Electricity
Electrical Engineering
ISBN:
9781337900348
Author:
Stephen L. Herman
Publisher:
Cengage Learning
Programmable Logic Controllers
Programmable Logic Controllers
Electrical Engineering
ISBN:
9780073373843
Author:
Frank D. Petruzella
Publisher:
McGraw-Hill Education
Fundamentals of Electric Circuits
Fundamentals of Electric Circuits
Electrical Engineering
ISBN:
9780078028229
Author:
Charles K Alexander, Matthew Sadiku
Publisher:
McGraw-Hill Education
Electric Circuits. (11th Edition)
Electric Circuits. (11th Edition)
Electrical Engineering
ISBN:
9780134746968
Author:
James W. Nilsson, Susan Riedel
Publisher:
PEARSON
Engineering Electromagnetics
Engineering Electromagnetics
Electrical Engineering
ISBN:
9780078028151
Author:
Hayt, William H. (william Hart), Jr, BUCK, John A.
Publisher:
Mcgraw-hill Education,