Q3/ A refrigeration unit of 20 T.R uses R-12 as a refrigerant and works between evaporating and condensing (10 degree) temperature of -20 °C and 37 °C. The vapor leaves the evaporator saturated and the liquid leaves the condenser saturated also. Find out the change of; (a) Mass flow rate of refrigerant, (b) Power consumed, (c) Volumetric efficiency, and (d) Piston displacement in the following to cases (i) The evaporation temperature is decreased to -27 °C due to a change of product while the condensing temperature is still constant, (ii) The condensing temperature is increased to 45 °C due to a change of outside conditions while the evaporating temperature is still constant at -20 °C.

Elements Of Electromagnetics
7th Edition
ISBN:9780190698614
Author:Sadiku, Matthew N. O.
Publisher:Sadiku, Matthew N. O.
ChapterMA: Math Assessment
Section: Chapter Questions
Problem 1.1MA
icon
Related questions
Question
Q3/ A refrigeration unit of 20 T.R uses R-12 as a refrigerant and works between evaporating and condensing
(10 degree)
temperature of -20 °C and 37 °C. The vapor leaves the evaporator saturated and the liquid leaves the condenser
saturated also. Find out the change of; (a) Mass flow rate of refrigerant, (b) Power consumed, (c) Volumetric
efficiency, and (d) Piston displacement in the following to cases (i) The evaporation temperature is decreased
to -27 °C due to a change of product while the condensing temperature is still constant, (ii) The condensing
temperature is increased to 45 °C due to a change of outside conditions while the evaporating temperature is still
constant at -20 °C.
Transcribed Image Text:Q3/ A refrigeration unit of 20 T.R uses R-12 as a refrigerant and works between evaporating and condensing (10 degree) temperature of -20 °C and 37 °C. The vapor leaves the evaporator saturated and the liquid leaves the condenser saturated also. Find out the change of; (a) Mass flow rate of refrigerant, (b) Power consumed, (c) Volumetric efficiency, and (d) Piston displacement in the following to cases (i) The evaporation temperature is decreased to -27 °C due to a change of product while the condensing temperature is still constant, (ii) The condensing temperature is increased to 45 °C due to a change of outside conditions while the evaporating temperature is still constant at -20 °C.
Expert Solution
steps

Step by step

Solved in 2 steps with 2 images

Blurred answer
Similar questions
Recommended textbooks for you
Elements Of Electromagnetics
Elements Of Electromagnetics
Mechanical Engineering
ISBN:
9780190698614
Author:
Sadiku, Matthew N. O.
Publisher:
Oxford University Press
Mechanics of Materials (10th Edition)
Mechanics of Materials (10th Edition)
Mechanical Engineering
ISBN:
9780134319650
Author:
Russell C. Hibbeler
Publisher:
PEARSON
Thermodynamics: An Engineering Approach
Thermodynamics: An Engineering Approach
Mechanical Engineering
ISBN:
9781259822674
Author:
Yunus A. Cengel Dr., Michael A. Boles
Publisher:
McGraw-Hill Education
Control Systems Engineering
Control Systems Engineering
Mechanical Engineering
ISBN:
9781118170519
Author:
Norman S. Nise
Publisher:
WILEY
Mechanics of Materials (MindTap Course List)
Mechanics of Materials (MindTap Course List)
Mechanical Engineering
ISBN:
9781337093347
Author:
Barry J. Goodno, James M. Gere
Publisher:
Cengage Learning
Engineering Mechanics: Statics
Engineering Mechanics: Statics
Mechanical Engineering
ISBN:
9781118807330
Author:
James L. Meriam, L. G. Kraige, J. N. Bolton
Publisher:
WILEY