Q2) This PLC is being used to start and stop an electric motor, and also to shut it down automatically if any of three "shutdown" conditions occur: Excessive vibration • Overcurrent (overload heater contact) • High winding temperature Power supply Digital inputs Digital outputs Pocess -To motor contactor Start l Stop. 120 VAC Oo Oo va 11 OL2N OGnd Com Com Vibration contact Temperature contact Overload contact The status of each shutdown contact is as follows: Vibration contact: closed when okay, opens when vibration becomes excessive Overload contact: closed when okay, opens when overloaded Temperature contact: open when okay, closes when hot Draw a PLC ladder-logic program to start and stop this motor.

Introductory Circuit Analysis (13th Edition)
13th Edition
ISBN:9780133923605
Author:Robert L. Boylestad
Publisher:Robert L. Boylestad
Chapter1: Introduction
Section: Chapter Questions
Problem 1P: Visit your local library (at school or home) and describe the extent to which it provides literature...
icon
Related questions
Question
Q2) This PLC is being used to start and stop an electric motor, and also to shut it down
automatically if any of three "shutdown" conditions occur:
• Excessive vibration
• Overcurrent (overload heater contact)
• High winding temperature
Power
supply
Digital
Inputs
Digital
outputs
Processor
To motor contactor
o x Oo
120 VAC
Start
Stop.
Oo va
NH
Oo va
L1
OL2N
X4
Com
Gnd
Com
Vibration contact
Temperature
contact
Overload
contact
The status of each shutdown contact is as follows:
Vibration contact: closed when okay, opens when vibration becomes excessive
Overload contact: closed when okay, opens when overloaded
Temperature contact: open when okay, closes when hot
Draw a PLC ladder-logic program to start and stop this motor.
Transcribed Image Text:Q2) This PLC is being used to start and stop an electric motor, and also to shut it down automatically if any of three "shutdown" conditions occur: • Excessive vibration • Overcurrent (overload heater contact) • High winding temperature Power supply Digital Inputs Digital outputs Processor To motor contactor o x Oo 120 VAC Start Stop. Oo va NH Oo va L1 OL2N X4 Com Gnd Com Vibration contact Temperature contact Overload contact The status of each shutdown contact is as follows: Vibration contact: closed when okay, opens when vibration becomes excessive Overload contact: closed when okay, opens when overloaded Temperature contact: open when okay, closes when hot Draw a PLC ladder-logic program to start and stop this motor.
Expert Solution
steps

Step by step

Solved in 2 steps with 2 images

Blurred answer
Knowledge Booster
Protection System for Machines
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.
Similar questions
Recommended textbooks for you
Introductory Circuit Analysis (13th Edition)
Introductory Circuit Analysis (13th Edition)
Electrical Engineering
ISBN:
9780133923605
Author:
Robert L. Boylestad
Publisher:
PEARSON
Delmar's Standard Textbook Of Electricity
Delmar's Standard Textbook Of Electricity
Electrical Engineering
ISBN:
9781337900348
Author:
Stephen L. Herman
Publisher:
Cengage Learning
Programmable Logic Controllers
Programmable Logic Controllers
Electrical Engineering
ISBN:
9780073373843
Author:
Frank D. Petruzella
Publisher:
McGraw-Hill Education
Fundamentals of Electric Circuits
Fundamentals of Electric Circuits
Electrical Engineering
ISBN:
9780078028229
Author:
Charles K Alexander, Matthew Sadiku
Publisher:
McGraw-Hill Education
Electric Circuits. (11th Edition)
Electric Circuits. (11th Edition)
Electrical Engineering
ISBN:
9780134746968
Author:
James W. Nilsson, Susan Riedel
Publisher:
PEARSON
Engineering Electromagnetics
Engineering Electromagnetics
Electrical Engineering
ISBN:
9780078028151
Author:
Hayt, William H. (william Hart), Jr, BUCK, John A.
Publisher:
Mcgraw-hill Education,