Q2) This PLC is being used to start and stop an electric motor, and also to shut it down automatically if any of three "shutdown" conditions occur: Excessive vibration Overcurrent (overload heater contact) High winding temperature Power supply Digital inputs Digital outputs Processor To motor contactor Do xo DO YO 120 VAC Start Stop o x2 Do Y2 H Øo x3 Oo Y3 L1 Øo x4 ØL2/N Com Gnd Com Vibration contact Temperature contact Overload contact The status of each shutdown contact is as follows:

Introductory Circuit Analysis (13th Edition)
13th Edition
ISBN:9780133923605
Author:Robert L. Boylestad
Publisher:Robert L. Boylestad
Chapter1: Introduction
Section: Chapter Questions
Problem 1P: Visit your local library (at school or home) and describe the extent to which it provides literature...
icon
Related questions
Question
100%
Q2) This PLC is being used to start and stop an electric motor, and also to shut it down
automatically if any of three “shutdown" conditions occur:
Excessive vibration
Overcurrent (overload heater contact)
High winding temperature
Power
supply
Digital
inputs
Digital
outputs
Processor
To motor contactor
ox oot
O YO
X1
120 VAC
Start Stop
Øo x2
のo Y2
N
Do x3
Do Y3
L1
O X4
ØL2/N
Com
Gnd
Com
Vibration contact
Temperature
contact
Overload
contact
The status of each shutdown contact is as follows:
Vibration contact: closed when okay, opens when vibration becomes excessive
Overload contact: closed when okay, opens when overloaded
Temperature contact: open when okay, closes when hot
Draw a PLC ladder-logic program to start and stop this motor.
Transcribed Image Text:Q2) This PLC is being used to start and stop an electric motor, and also to shut it down automatically if any of three “shutdown" conditions occur: Excessive vibration Overcurrent (overload heater contact) High winding temperature Power supply Digital inputs Digital outputs Processor To motor contactor ox oot O YO X1 120 VAC Start Stop Øo x2 のo Y2 N Do x3 Do Y3 L1 O X4 ØL2/N Com Gnd Com Vibration contact Temperature contact Overload contact The status of each shutdown contact is as follows: Vibration contact: closed when okay, opens when vibration becomes excessive Overload contact: closed when okay, opens when overloaded Temperature contact: open when okay, closes when hot Draw a PLC ladder-logic program to start and stop this motor.
Expert Solution
trending now

Trending now

This is a popular solution!

steps

Step by step

Solved in 2 steps with 1 images

Blurred answer
Knowledge Booster
Electromagnetics Torque and Power
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Introductory Circuit Analysis (13th Edition)
Introductory Circuit Analysis (13th Edition)
Electrical Engineering
ISBN:
9780133923605
Author:
Robert L. Boylestad
Publisher:
PEARSON
Delmar's Standard Textbook Of Electricity
Delmar's Standard Textbook Of Electricity
Electrical Engineering
ISBN:
9781337900348
Author:
Stephen L. Herman
Publisher:
Cengage Learning
Programmable Logic Controllers
Programmable Logic Controllers
Electrical Engineering
ISBN:
9780073373843
Author:
Frank D. Petruzella
Publisher:
McGraw-Hill Education
Fundamentals of Electric Circuits
Fundamentals of Electric Circuits
Electrical Engineering
ISBN:
9780078028229
Author:
Charles K Alexander, Matthew Sadiku
Publisher:
McGraw-Hill Education
Electric Circuits. (11th Edition)
Electric Circuits. (11th Edition)
Electrical Engineering
ISBN:
9780134746968
Author:
James W. Nilsson, Susan Riedel
Publisher:
PEARSON
Engineering Electromagnetics
Engineering Electromagnetics
Electrical Engineering
ISBN:
9780078028151
Author:
Hayt, William H. (william Hart), Jr, BUCK, John A.
Publisher:
Mcgraw-hill Education,