Problem 3 - Air Conditioning ( An office building has a window air conditioner with a COP of 2 that consumes 2 kW of electricity. Computers, terminals, printers and other equipment are in the room with a total rate power of 8.4 kW. At any given time, 40% of the equipment is assumed to be operating. There are seven employees working in the building at any given time and each is assumed to generate heat at a rate of 100 W. The office building also gains heat due to direct solar heating at a rate of 3 kW during the middle of the day Is the window air conditioner large enough to meet the cooling load? If not, how many portable air conditioners that can remove heat at a rate of 7,000 Btu/h would be required to meet the cooling load? Be sure to draw a schematic, draw a control boundary and apply the first law to solve this problem. Do not consider the electricity consumed by the window air conditioner or other air conditioners when computing the load. Note that the cooling load is the total amount of heat an air conditioner must remove from a space.

Elements Of Electromagnetics
7th Edition
ISBN:9780190698614
Author:Sadiku, Matthew N. O.
Publisher:Sadiku, Matthew N. O.
ChapterMA: Math Assessment
Section: Chapter Questions
Problem 1.1MA
icon
Related questions
Question
Okkk
Problem 3 - Air Conditioning (
An office building has a window air conditioner with a COP of 2 that consumes 2 kW of
electricity. Computers, terminals, printers and other equipment are in the room with a total
rate power of 8.4 kW. At any given time, 40% of the equipment is assumed to be operating.
There are seven employees working in the building at any given time and each is assumed to
generate heat at a rate of 100 W. The office building also gains heat due to direct solar heating
at a rate of 3 kW during the middle of the day Is the window air conditioner large enough to
meet the cooling load? If not, how many portable air conditioners that can remove heat at a
rate of 7,000 Btu/h would be required to meet the cooling load?
Be sure to draw a schematic, draw a control boundary and apply the first law to solve this
problem. Do not consider the electricity consumed by the window air conditioner or other air
conditioners when computing the load. Note that the cooling load is the total amount of heat
an air conditioner must remove from a space.
Transcribed Image Text:Problem 3 - Air Conditioning ( An office building has a window air conditioner with a COP of 2 that consumes 2 kW of electricity. Computers, terminals, printers and other equipment are in the room with a total rate power of 8.4 kW. At any given time, 40% of the equipment is assumed to be operating. There are seven employees working in the building at any given time and each is assumed to generate heat at a rate of 100 W. The office building also gains heat due to direct solar heating at a rate of 3 kW during the middle of the day Is the window air conditioner large enough to meet the cooling load? If not, how many portable air conditioners that can remove heat at a rate of 7,000 Btu/h would be required to meet the cooling load? Be sure to draw a schematic, draw a control boundary and apply the first law to solve this problem. Do not consider the electricity consumed by the window air conditioner or other air conditioners when computing the load. Note that the cooling load is the total amount of heat an air conditioner must remove from a space.
Expert Solution
trending now

Trending now

This is a popular solution!

steps

Step by step

Solved in 3 steps with 2 images

Blurred answer
Knowledge Booster
Work and Heat
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, mechanical-engineering and related others by exploring similar questions and additional content below.
Similar questions
Recommended textbooks for you
Elements Of Electromagnetics
Elements Of Electromagnetics
Mechanical Engineering
ISBN:
9780190698614
Author:
Sadiku, Matthew N. O.
Publisher:
Oxford University Press
Mechanics of Materials (10th Edition)
Mechanics of Materials (10th Edition)
Mechanical Engineering
ISBN:
9780134319650
Author:
Russell C. Hibbeler
Publisher:
PEARSON
Thermodynamics: An Engineering Approach
Thermodynamics: An Engineering Approach
Mechanical Engineering
ISBN:
9781259822674
Author:
Yunus A. Cengel Dr., Michael A. Boles
Publisher:
McGraw-Hill Education
Control Systems Engineering
Control Systems Engineering
Mechanical Engineering
ISBN:
9781118170519
Author:
Norman S. Nise
Publisher:
WILEY
Mechanics of Materials (MindTap Course List)
Mechanics of Materials (MindTap Course List)
Mechanical Engineering
ISBN:
9781337093347
Author:
Barry J. Goodno, James M. Gere
Publisher:
Cengage Learning
Engineering Mechanics: Statics
Engineering Mechanics: Statics
Mechanical Engineering
ISBN:
9781118807330
Author:
James L. Meriam, L. G. Kraige, J. N. Bolton
Publisher:
WILEY