PA FAB DA = 2000 MW DB = 1000 MW Figure P6.2 Two-bus power system for Problems 6.2, 6.3, 6.4, 6.10 and 6.11 6.2 Consider the two-bus power system shown in Figure P6.2. The marginal cost of production of the generators connected to buses A and B are given respectively by the following expressions: MCA = 20 + 0.03 PA $/MWh MCB = 15 +0.02 Pg $/MWh Assume that the demand is constant and insensitive to price, that energy is sold at its marginal cost of production and that there are no limits on the output of the generators. Calculate the price of electricity at each bus, the production of each generator and the flow on the line for the following cases: а. The line between buses A and B is disconnected b. The line between buses A and B is in service and has an unlimited capacity The line between buses A and B is in service and has an unlimited capacity, but the maximum output of Generator B is 1500 MW с. d. The line between buses A and B is in service and has an unlimited capac- ity, but the maximum put of Generator A is 900 MW. The output of Generator B is unlimited. The line between buses A and B is in service but its capacity is limited to 600 MW. The output of the generators is unlimited. е.

Introductory Circuit Analysis (13th Edition)
13th Edition
ISBN:9780133923605
Author:Robert L. Boylestad
Publisher:Robert L. Boylestad
Chapter1: Introduction
Section: Chapter Questions
Problem 1P: Visit your local library (at school or home) and describe the extent to which it provides literature...
icon
Related questions
icon
Concept explainers
Question
A
В
PA
FAB
Рв
DA = 2000 MW
DB = 1000 MW
Figure P6.2 Two-bus power system for Problems 6.2, 6.3, 6.4, 6.10 and 6.11
6.2 Consider the two-bus power system shown in Figure P6.2. The marginal cost of
production of the generators connected to buses A and B are given respectively
by the following expressions:
MCA
= 20 + 0.03 PA $/MWh
MCB = 15 + 0.02 Pg $/MWh
Assume that the demand is constant and insensitive to price, that energy is sold
at its marginal cost of production and that there are no limits on the output of
the generators. Calculate the price of electricity at each bus, the production of
each generator and the flow on the line for the following cases:
а.
The line between buses A and B is disconnected
b. The line between buses A and B is in service and has an unlimited capacity
The line between buses A and B is in service and has an unlimited capacity,
but the maximum output of Generator B is 1500 MW
с.
d. The line between buses A and B is in service and has an unlimited capac-
ity, but the maximum output of Generator A is 900 MW. The output of
Generator B is unlimited.
The line between buses A and B is in service but its capacity is limited to
600 MW. The output of the generators is unlimited.
е.
Transcribed Image Text:A В PA FAB Рв DA = 2000 MW DB = 1000 MW Figure P6.2 Two-bus power system for Problems 6.2, 6.3, 6.4, 6.10 and 6.11 6.2 Consider the two-bus power system shown in Figure P6.2. The marginal cost of production of the generators connected to buses A and B are given respectively by the following expressions: MCA = 20 + 0.03 PA $/MWh MCB = 15 + 0.02 Pg $/MWh Assume that the demand is constant and insensitive to price, that energy is sold at its marginal cost of production and that there are no limits on the output of the generators. Calculate the price of electricity at each bus, the production of each generator and the flow on the line for the following cases: а. The line between buses A and B is disconnected b. The line between buses A and B is in service and has an unlimited capacity The line between buses A and B is in service and has an unlimited capacity, but the maximum output of Generator B is 1500 MW с. d. The line between buses A and B is in service and has an unlimited capac- ity, but the maximum output of Generator A is 900 MW. The output of Generator B is unlimited. The line between buses A and B is in service but its capacity is limited to 600 MW. The output of the generators is unlimited. е.
Expert Solution
trending now

Trending now

This is a popular solution!

steps

Step by step

Solved in 3 steps with 2 images

Blurred answer
Knowledge Booster
Load flow analysis
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.
Similar questions
Recommended textbooks for you
Introductory Circuit Analysis (13th Edition)
Introductory Circuit Analysis (13th Edition)
Electrical Engineering
ISBN:
9780133923605
Author:
Robert L. Boylestad
Publisher:
PEARSON
Delmar's Standard Textbook Of Electricity
Delmar's Standard Textbook Of Electricity
Electrical Engineering
ISBN:
9781337900348
Author:
Stephen L. Herman
Publisher:
Cengage Learning
Programmable Logic Controllers
Programmable Logic Controllers
Electrical Engineering
ISBN:
9780073373843
Author:
Frank D. Petruzella
Publisher:
McGraw-Hill Education
Fundamentals of Electric Circuits
Fundamentals of Electric Circuits
Electrical Engineering
ISBN:
9780078028229
Author:
Charles K Alexander, Matthew Sadiku
Publisher:
McGraw-Hill Education
Electric Circuits. (11th Edition)
Electric Circuits. (11th Edition)
Electrical Engineering
ISBN:
9780134746968
Author:
James W. Nilsson, Susan Riedel
Publisher:
PEARSON
Engineering Electromagnetics
Engineering Electromagnetics
Electrical Engineering
ISBN:
9780078028151
Author:
Hayt, William H. (william Hart), Jr, BUCK, John A.
Publisher:
Mcgraw-hill Education,