Match the following. Prompts Breather Answers 2 Strainer 3 Regulator Select match Filters ambient air before entering the compressor. Select match Expels air when excess pressure is sensed. Select match Sets the operating pressure of the pneumatic system. Moisture Separator Select match 5 Aftercooler Select match 6 Air Heater Select match 7 Silencer Removes moisture from the compressed air. Works in conjunction with the strainer. Provides manual control of air flow. Used to reduce pulsations and also can be used as an emergency backup supply. Select match Used to prevent freezing of exhaust ports in cold environments 8 Shut off/on valve Select match 9 PRV Select match 10) Accumulator Select match Sintered brass usually placed on exhaust ports. Removes contaminants from the pressurized air. A cold-water heat exchanger used to condense moisture from the air.

Elements Of Electromagnetics
7th Edition
ISBN:9780190698614
Author:Sadiku, Matthew N. O.
Publisher:Sadiku, Matthew N. O.
ChapterMA: Math Assessment
Section: Chapter Questions
Problem 1.1MA
icon
Related questions
Question

Match the following in the right order

Match the following.
Prompts
Breather
Answers
2
Strainer
3 Regulator
Select match
Filters ambient air before entering the compressor.
Select match
Expels air when excess pressure is sensed.
Select match
Sets the operating pressure of the pneumatic system.
Moisture Separator
Select match
5
Aftercooler
Select match
6
Air Heater
Select match
7 Silencer
Removes moisture from the compressed air. Works in
conjunction with the strainer.
Provides manual control of air flow.
Used to reduce pulsations and also can be used as an emergency
backup supply.
Select match
Used to prevent freezing of exhaust ports in cold environments
8
Shut off/on valve
Select match
9
PRV
Select match
10) Accumulator
Select match
Sintered brass usually placed on exhaust ports.
Removes contaminants from the pressurized air.
A cold-water heat exchanger used to condense moisture from
the air.
Transcribed Image Text:Match the following. Prompts Breather Answers 2 Strainer 3 Regulator Select match Filters ambient air before entering the compressor. Select match Expels air when excess pressure is sensed. Select match Sets the operating pressure of the pneumatic system. Moisture Separator Select match 5 Aftercooler Select match 6 Air Heater Select match 7 Silencer Removes moisture from the compressed air. Works in conjunction with the strainer. Provides manual control of air flow. Used to reduce pulsations and also can be used as an emergency backup supply. Select match Used to prevent freezing of exhaust ports in cold environments 8 Shut off/on valve Select match 9 PRV Select match 10) Accumulator Select match Sintered brass usually placed on exhaust ports. Removes contaminants from the pressurized air. A cold-water heat exchanger used to condense moisture from the air.
Expert Solution
steps

Step by step

Solved in 1 steps with 1 images

Blurred answer
Recommended textbooks for you
Elements Of Electromagnetics
Elements Of Electromagnetics
Mechanical Engineering
ISBN:
9780190698614
Author:
Sadiku, Matthew N. O.
Publisher:
Oxford University Press
Mechanics of Materials (10th Edition)
Mechanics of Materials (10th Edition)
Mechanical Engineering
ISBN:
9780134319650
Author:
Russell C. Hibbeler
Publisher:
PEARSON
Thermodynamics: An Engineering Approach
Thermodynamics: An Engineering Approach
Mechanical Engineering
ISBN:
9781259822674
Author:
Yunus A. Cengel Dr., Michael A. Boles
Publisher:
McGraw-Hill Education
Control Systems Engineering
Control Systems Engineering
Mechanical Engineering
ISBN:
9781118170519
Author:
Norman S. Nise
Publisher:
WILEY
Mechanics of Materials (MindTap Course List)
Mechanics of Materials (MindTap Course List)
Mechanical Engineering
ISBN:
9781337093347
Author:
Barry J. Goodno, James M. Gere
Publisher:
Cengage Learning
Engineering Mechanics: Statics
Engineering Mechanics: Statics
Mechanical Engineering
ISBN:
9781118807330
Author:
James L. Meriam, L. G. Kraige, J. N. Bolton
Publisher:
WILEY