Manufacturer's performance data for a water pump operating at 1725 rpm and room temperature (Example 14–11)* V, cm/s Н, ст Npump 100 180 32 200 185 54 300 175 70 400 170 79 500 150 81 600 95 66 700 54 38
After graduation, you work for a pump manufacturing company. One of your company’s best-selling products is a water pump, which we shall call pump A. Its impeller diameter is DA = 6.0 cm, and its performance data when operating at n. A = 1725 rpm (?A = 180.6 rad/s) are shown in Table.The marketing research department is recommending that the company design a new product, namely, a larger pump (which we shall call pump B) that will be used to pump liquid refrigerant R-134a at room temperature. The pump is to be designed such that its best efficiency point occurs as close as possible to a volume flow rate of V. B = 2400 cm3 /s and at a net head of HB = 450 cm (of R-134a). The chief engineer (your boss) tells you to perform some preliminary analyses using pump scaling laws to determine if a geometrically scaled-up pump could be designed and built to meet the given requirements. (a) Plot the performance curves of pump A in both dimensional and dimensionless form, and identify the best efficiency point. (b) Calculate the required pump diameter DB, rotational speed n.B, and brake horsepower bhpB for the new product.