INSTRUCTION: Round your answer to six decimal places, and round your answer to three decimal places for power factor. Show your complete solution and box your final answer. 1. Assume line voltage "A" as reference and include the 30 degree phase shift. A three phase source, 3-wire, 4160V, negative sequence is loaded with the following single phase loads: Zab Zbc 5253.13° : 10253.13° 2; === Zca 10253.13° 42; Zan 10453.13° Q Zbn 5253.13° 2; Zen 5253.13° (2; Determine: a. the overall power factor; b. the total line a positive sequence; c. the total line b negative sequence; d. the total line c zero sequence; e. the neutral current.

Introductory Circuit Analysis (13th Edition)
13th Edition
ISBN:9780133923605
Author:Robert L. Boylestad
Publisher:Robert L. Boylestad
Chapter1: Introduction
Section: Chapter Questions
Problem 1P: Visit your local library (at school or home) and describe the extent to which it provides literature...
icon
Related questions
Question
Subject: Electrical Engineering Subject: Power System Analysis Instruction: Use handwritten Solution and follow the instruction. Please write the complete step by step solution and box your final answer. Thankyou so much.
INSTRUCTION: Round your answer to six decimal places, and round your
answer to three decimal places for power factor. Show your complete solution and
box your final answer.
1. Assume line voltage "A" as reference and include the 30 degree phase shift. A
three phase source, 3-wire, 4160V, negative sequence is loaded with the following
single phase loads:
Zab
Zbc
5253.13° :
10253.13° 2;
===
Zca 10253.13° 42;
Zan
10453.13° Q
Zbn
5253.13° 2;
Zen
5253.13° (2;
Determine:
a. the overall power factor;
b. the total line a positive sequence;
c. the total line b negative sequence;
d. the total line c zero sequence;
e. the neutral current.
Transcribed Image Text:INSTRUCTION: Round your answer to six decimal places, and round your answer to three decimal places for power factor. Show your complete solution and box your final answer. 1. Assume line voltage "A" as reference and include the 30 degree phase shift. A three phase source, 3-wire, 4160V, negative sequence is loaded with the following single phase loads: Zab Zbc 5253.13° : 10253.13° 2; === Zca 10253.13° 42; Zan 10453.13° Q Zbn 5253.13° 2; Zen 5253.13° (2; Determine: a. the overall power factor; b. the total line a positive sequence; c. the total line b negative sequence; d. the total line c zero sequence; e. the neutral current.
Expert Solution
steps

Step by step

Solved in 2 steps

Blurred answer
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Introductory Circuit Analysis (13th Edition)
Introductory Circuit Analysis (13th Edition)
Electrical Engineering
ISBN:
9780133923605
Author:
Robert L. Boylestad
Publisher:
PEARSON
Delmar's Standard Textbook Of Electricity
Delmar's Standard Textbook Of Electricity
Electrical Engineering
ISBN:
9781337900348
Author:
Stephen L. Herman
Publisher:
Cengage Learning
Programmable Logic Controllers
Programmable Logic Controllers
Electrical Engineering
ISBN:
9780073373843
Author:
Frank D. Petruzella
Publisher:
McGraw-Hill Education
Fundamentals of Electric Circuits
Fundamentals of Electric Circuits
Electrical Engineering
ISBN:
9780078028229
Author:
Charles K Alexander, Matthew Sadiku
Publisher:
McGraw-Hill Education
Electric Circuits. (11th Edition)
Electric Circuits. (11th Edition)
Electrical Engineering
ISBN:
9780134746968
Author:
James W. Nilsson, Susan Riedel
Publisher:
PEARSON
Engineering Electromagnetics
Engineering Electromagnetics
Electrical Engineering
ISBN:
9780078028151
Author:
Hayt, William H. (william Hart), Jr, BUCK, John A.
Publisher:
Mcgraw-hill Education,